Chapter 3 Specifications
3-13
RAS Interfaces
D-sub 9 pin socket connector
Be sure to use only the rated voltage level when using pin #1 (DC+12V) for
external power output. Failure to do so can lead to a unit malfunction or accident.
Interfit Bracket #4-40 (UNC)
Pin Arrangement Pin No. Signal Name Description
1+12 V
Output Current: 100mA or less
Output Voltage: DC12V±5%
2 DOUT0(+) Data out 0(+)
3 DOUT1(+) Data out 1(+)
4 DIN0(+) Data in 0(+)
5 DIN1(+) Data in 1(+)
*1
*1 Can be used for inputting the reset signals.
6 GND Ground
7 DOUT0(-) Data out 0(-)
8 DOUT1(-) Data out 1(-)
9 DINCOM Data in c ommon
For further details of the RAS function, see the “PL3000 Series Reference Manual”.
(PL unit sid e)
9
6
1
5