User Manual

Chapter 3 Specifications
3-3
3.1.2 Environmental Specifications
Physical
Surrounding Air
Temperature
0 to 50°C: without HDD
*1
5 to 50°C: with HDD
*1
*1 It is regarding whether SSD installing.
Storage
Temperature
20 to +60°C
Ambient Humidity
10 to 90%RH (Not condensing, wet bulb temperature: 39°C or less.
Wet bulb temperature with HDD
*1
: 29°C or less.)
S torage Humidity 10 to 90%RH (Not condensing, wet bulb temperature: 39°C or less.)
Dust Free of dust
Pollution Degree For use in Pollution Degree 2 environment
Corrosive gas Free of corrosive gases
Atmosphere
(Using height)
800 to 1114 hPa (-300 to 2,000 meters above sea-level and below)
Mechanical
Vibration
Resistance
Without HDD
*1
IEC/EN61131-2 compliant
5 to 9 Hz single-amplitude 3.5mm [0.14in.]
9 to 150 Hz constant-acceleration 9.8m/s
2
X, Y, Z directions for 10 cycle (100 minute)
With HDD
*1
10 to 57 Hz single-amplitude 0.075mm [0.003in.]
57 to 150 Hz constant-acceleration 9.8m/s
2
X, Y, Z directions for 10 cycle (80 minute)
Electrical
Noise Immunity
Noise Voltage: 1500V
P-P
Pulse Duration: 50ns, 500ns, 1µs
Rise Time: 1ns
(via noise simulator)
Electrostatic
Discharge
Immunity
6kV (complies with IEC/EN 61000-4-2 Level 3)
When using any of the PL’s optional devices, be sure to check that device’s
specifications for any special conditions or cautions that may apply to its use.
Be aware that not onl y does the Hard Disk/SSD have a fixed lifetime, but that
accidents can always occur . Therefore, be sure to back up your Hard Disk/SSD's
data regularly, or prepare another Hard Disk/SSD unit that can be used for
backup.
The Hard Disk lifetime given here may be redu ced due to unforeseen
environmental factors. The following table shows the Hard Disk lifetime general
factors.
APL3000-HD60 (Rev.A)
APL3000-HD60 (Rev.B or later)
APL3000-HD250
Factors
Operating temperature: 20°C,
333 hours of operation per month.
(HDD access frequency of 20% or
less)
Operating temperature: 20°C,
732 hours of operation per month.
(HDD access frequency of 50% or
less)
Lifetime
20,000 hours (of operation) or
approximately 5 years, whichever
comes first.
30,000 hours (of operation) or
approximately 5 years, whichever
comes first.