User Manual
Chapter 6 Maintenance
6-5
6.3 Replacing the Inst allation Gasket
The installation gasket provides protection against dust and moisture.
Installation Gasket Attachment Procedure
(1) Place the PL on a flat, level s u rfa ce facing the display face downwards.
(2) Remove the gasket from the PL.
(3) Attach the new gasket to the PL. Be sure to insert the gasket into the PL groove so that the gasket’s
groove faces downwards.
(4) Check that the gasket is att a ched correctly to the PL.
• A gasket which has been used for a long period of time may have scratches or
dirt on it, and could have lost much of its water resistance. Be sure to change the
gasket at least once a year, or when scratches or dirt become visible.
• The model number of the PL unit installation gaskets is described below.
PL-3600T Series CA7-WPG12-01
PL-3600K Series
PL-3700T Series
CA7-WPG15-01
PL-3700K Series CA7-WPG15K-01
PL-3900T Series CA7-WPG19-01
Gasket Seam
Gasket
Installation Groove
PL Rear Face