Chapter 3 PL Monitoring Features
3-43
Do not install the battery driver when a battery unit is not mounted; otherwise, the Battery
Unit Disconnected Error will be displayed. To recover the error , the battery driver should be
uninstalled.
For procedure to uninstall the battery driver, refer to the following section.
Remaining level of battery power supply cannot be monitored.
The battery unit and driver communicate via COM2 port. From [Integrated Device
Configuration] in the [Advanced] menu on the System Setup Screen, select [I/O
Device Configuration], and set the [COM Port2:] option to [Enable]. (The factory
default setting is [Enable].)
The system may not enter standby or hibernation mode normally depending on
your applications or other drivers being used.
When using battery power, the external COM2 port cannot be used.
Monitoring of the Battery status is enabled only when a battery is mounted.
Battery units cannot be used with pre-installed OS type PL units that have SSD (solid-state
drive) units.
SEE
5.1 Problems and Countermeasures (page5-2)