User Manual

6
Enviro nmental Specifications
When using any of the PL’s optional devices, be sure to che ck that device’s specifica-
tions for any special conditi ons or cautions that may apply to its use.
Be aware that not only does the HDD/SSD have a fi xe d l i fetime, but that accidents
can always occur. Therefore, be sure to back up your HDD/SSD’s data regularl y, or
prepare another HDD/SSD unit that can be used for backup.
The Hard Disk lifetime given here may be reduced due to unforeseen environmental
factors, however, generally speaking, the disk should last for 20,000 hours (of opera-
tion) or approximately 5 years, whichever comes first at an operating temperature of
20
°C and 333 hours of operation per month. (HDD access frequency of 20% or less)
Using the Hard Disk in an environment that is excessively hot and/or humid will
shorten the disk’s usage lifetime. A wet bulb temperature of 29
°C or less is recom-
mended. This is equivalent to the following data.
In order to extend the li fetime of the hard disk, Pro-face recommends you set the
Windows
®
2000’s [C ontrol panel]-[Power Management option]-[Turn off hard disks]
selection or the Windows
®
XP’s [Control panel]-[Performance and Maintenance]-
[Power Management option]-[ Turn off hard disks] selection to turn the hard disk off
when the unit is not being operated. A setting of 5 minutes is recommended.
Do not vibrate the hard disk continuously at the same f requency. Doing so may cause
the hard disk to reduce tr ansfer speeds or stop temporarily.
Weight increases by about 1.4kg with a battery unit. Please refer to PL3000 Series Hardware
Manual for other specifications.
Internal Switches
To operate the internal switches, uninstall the control box and the front module.
With the PL-3000B series unit, remove the switch cover from the control box.
Physical
Surrounding Air
Temperature
5 to 45°C
Storage Tem perature -20 to +60°C (when packed)
Ambient Humidity
10 to 90% RH (Not condensing, wet bulb temperature: 39°C or
less. Wet bulb temper ature with HDD: 29°C or less.)
Storage Humidity 10 to 90% RH (Not condensing, wet bulb temperature:39°C or less.)
Dust Free of dust
Pollution Degree For use in Pollution Degree 2 environment
Temperature at 35°C at 40°C
Humidity no higher than 64% RH no higher than 44% RH
SEE
Installation/uninstallation of the front module and the control box (18 page)