User Manual

5
General Specif icati ons
Electr ical Specifications
Power Supply
AC type
Input Voltage AC100 to 240V
Rated Voltage AC85 to 264V
Rated Frequency 50/60Hz
Allowable Frequency Range 47 to 63Hz
Allowable Voltage Drop
1 cycle or less
(Voltage drop interval must be 1s or more.)
*1
*1 When the ba ttery is not charged, de pending on the to tal of the ex pansion slot power and the exte rnal
load power, the length of the allowable voltage drop will be 20 ms or less (excluding PL3000B
series). For details, refer to the graphs below.
Power Consumption 145VA or less
In-Rush Current 40A or less
Voltage Endurance
AC1500V 20mA for 1 minute
(between charging and FG terminals)
Insulation Resistance
DC500V 10M (min.)
(between charging and FG terminals)
Allowable Range
(ms)
20
18
20
40 (W)
0
35
Allowable Ra nge
(ms)
20
14
35 40
(W)
015
Allowable Range
PL-3700* Se ries
25 40 (W)
(ms)
20
15
0
PL-3600* Seri es
PL-3900T Series