unit without adjusting the Panel Cut size.
As shown in the following diagram, simply
remove 7 screws from the upper and lower
positions to remove attachments from the
PL-3600K series unit.
Panel Cut size without attachment
(2) Confirm that the installation gasket is
attached to the PL unit and then plac e the
PL unit into the panel from the front.
It is strongly recomme nded that you
use the insta ll at i on ga sket, sinc e i t
absorbs vibration in addition to repel-
ling water.
For the procedure for attaching the
installation gasket, refer to “PL3000
Series Hardware Manual”.
(3) Insert each fasteners hook into the slot
and tighten it with a screwdriver. Tighten
the screws gradually in an even, criss-
cross pattern.
The number of the slots varies depending
on the model.
PL-3600T Series : 4 slots
PL-3600K/3700T Series: 8 slots
PL-3700K/3900T Series: 12 slots
PL X Y
Panel
thickness
PL-3600K Seri es
(3612KPM/
4612KPM
compatible)
383.54
[15.10]
275.59
[10.85]
1.6[0.06]
to
10.0[0.39]
Attachments
Insertion Slots
Locations of the 4 slots
Insertion
Slots
Locations of the 8 slots
Insertion
Slots
Locations of the 12 slots