Instruction Manual

ST3000 Series Hardware Manual
3-20
Serial Interface (COM2)
This interface is used to connect an RS-422/RS-485
*1
serial cable. A D-Sub 9-pin plug connector is used.
<ST unit side>
<Cable side>
*1 RS-485 is compliant with AST-3301B / AST-3301S with revision code "B" or later. For all other models,
all revisions support RS-485.
About Revision (page 12)
ST Connector XM2C-0942-502LX <OMRON Co.>
Interfit Bracket #4-40 inch screws are used.
Recommended Cable Connector XM2D-0901 <OMRON Co.>
Recommended Cable Cover XM2S-0913 <OMRON Co.>
Recommended Jack Screw XM2Z-0073 <OMRON Co.>
Pin
Arrangement
Pin No.
RS-422/RS-485
*1
Signal Name Direction Meaning
1 RDA Input Receive Data A(+)
2 RDB Input Receive Data B(-)
3 SDA Output Send Data A(+)
4 ERA Output Data Terminal Ready A(+)
5 SG - Signal Ground
6 CSB Input Send Possible B(-)
7 SDB Output Send Data B(-)
8 CSA Input Send Possible A(+)
9 ERB Output Data Terminal Ready B(-)
Shell FG -
Frame Ground
(Common with SG)
SEE
9
6
5
1
(ST unit side)