Instruction Manual

Chapter 5 Maintenance
5-5
The gasket must be inserted correctly into the groove for the ST’s moisture
resistance to be equivalent to IP65f.
Since the gasket is flexible but not elastic, be careful not to stretch it
unnecessarily, as doing so could tear the gasket.
Be sure the gasket’s seam is not inserted into any of the unit’s corners, only in
the straight sections of the groove. Inserting it into a corner may lead to its
eventually tearing.
To ensure stable resistance against dust and moisture, insert the gasket so that
the seam is at the bottom of the ST unit.
The upper surface of the gasket should protrude approximately 2.0mm[0.08in]
out from the groove. Be sure to check that the gasket is correctly inserted before
installing the ST into a panel.
2.0mm[0.08in]