RMW8 Wireless System
RMW8 INDICE 1. Precauzioni d’uso ................................................................................................................................................. 3 2. Descrizione ............................................................................................................................................................ 6 3. a) b) c) d) Funzioni E Controlli ...................................................................................................................
RMW8 1. Precauzioni d’uso AVVERTENZA: Per ridurre il rischio di folgorazione, non rimuovere il coperchio (o il pannello posteriore). All’interno non sono contenute parti riparabili dall’utente; affidare la riparazione a personale qualificato. ATTENZIONE: Per ridurre il rischio d’incendio o di folgorazione, non esporre questo apparecchio alla pioggia o all’umidità.
RMW8 Protezione del cavo di alimentazione Il cavo di alimentazione elettrica deve essere installato in modo che non venga calpestato o pizzicato da oggetti posti sopra o contro, prestando particolare attenzione a cavi e spine, prese a muro. Pulizia Quando l’unità deve essere pulita, è possibile eliminare la polvere utilizzando un getto d’aria compressa o un panno inumidito.
RMW8 IMPORTANTI NORME DI SICUREZZA Installare seguendo le istruzioni. Il voltaggio d’alimentazione dell’unità è abbastanza elevato: per evitare il rischio di scosse elettriche, non installare, collegare o sconnettere l’alimentazione quando l’apparato è acceso. Non aprire mai l’apparecchiatura: all’interno non esistono parti utilizzabili dall’utente. Se si avverte uno strano odore proveniente dall’apparato, spegnerlo immediatamente e sconnettere il cavo dell’alimentazione.
RMW8 Grazie per aver scelto un prodotto PROEL e della fiducia riposta nel nostro marchio, sinonimo di professionalità, accuratezza, elevata qualità ed affidabilità. Tutti i nostri prodotti sono conformi alle normative CE per utilizzazione continua in impianti di diffusione sonora. 2. Descrizione Il sistema radiomicrofonico RMW8 è composto da 3 parti : ricevitore RMW8, trasmettitore a mano WML e trasmettitore tascabile WHL, riponibili nella comoda custodia in ABS in dotazione.
RMW8 b) Pannello Posteriore 6 5 4 3 2 1 1. UP / DOWN Selezione manuale delle frequenze pre-selezionate da 0 a 99 tramite la pressione sui tasti UP e DOWN. 2. Menu Tenendo premuto il pulsante per 1,5 secondi, si attiva la funzione Sq (vedi la sezione squelch Control) 3. LOW MID HI Selezione del livello d’uscita del BALANCED OUT. Level: LOW -12dB, MID -6dB, HIGH 0 dB. 4. Uscita Audio sbilanciata su Jack 6.3 mono 5. Uscita Audio bilanciata su XLR-M 6.
RMW8 d) Trasmettitore Bodypack 1. Display Il display LCD mostra: simbolo d’antenna (se TX e RX sono agganciati), frequenza di lavoro, livello di carica della batteria, CANALE, potenza di trasmissione (PL), LOCK. 2. CH/ON Premendo per un secondo questo tasto il trasmettitore si accende, alle successive pressioni si passa ciclicamente alle seguenti funzioni: CHANNEL / PL / LOCK. Per spegnere il trasmettitore premere il tasto per un secondo. 3. SELECT Nella modalità funzioni permette di scegliere i valori. 4.
RMW8 4. Operazioni a) Ricevitore RMW8 Squelch Control Entrare nella modalità SQUELCH premendo il tasto MENU, il display mostrerà un numero tra 0 e 10 che indica il valore corrente della soglia come riportato dalla tabella: Numero Soglia di Squelch 1 95,0 dB 2 91,7 dB 3 88,3 dB 4 85,0 dB 5 81,7 dB 6 78,3 dB 7 75,0 dB 8 71,7 dB 9 68,3 dB 10 65,0 dB AUDIO METER dB RF METER Selezionare il livello desiderato con i tasti UP e DOWN, premere il tasto MEM per uscire dalla selezione.
RMW8 Funzione Lock Entrare nella modalità Look/unlock premendo quattro volte il tasto CH/ON, il display mostrerà Look o unlock a seconda di quale è settato correntemente, mediante il tasto SELECT selezionare o deselezionare il blocco. Dopo alcuni secondi dall’ultima digitazione il display si riporta sulla schermata iniziale.
RMW8 6. Tabella Frequenze (798.000-827.000mhz) CH 0 CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH8 CH 9 CH 10 CH 11 798.125 798.325 798.525 798.725 798.925 799.125 799.325 799.525 799.725 799.925 800.125 800.325 CH 12 CH 13 CH 14 CH 15 CH 16 CH 17 CH 18 CH 19 CH 20 CH 21 CH 22 CH 23 800.525 800.725 800.925 801.125 801.325 801.525 801.725 801.925 802.125 802.325 802.525 802.725 CH 24 CH 25 CH 26 CH 27 CH 28 CH 28 CH 30 CH 31 CH 32 CH 33 CH 34 CH 35 802.
RMW8 MODEL Trasmission mode Frequency band: Frequency response: Frequency stability: T.H.
RMW8 1. Safety Instructions CAUTION: To reduce the risk of electric shock do not the remove cover or back panel. No user serviceable parts inside. Refer servicing to qualified personnel only. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. This symbol is intended to alert the user of the presence of un-insulated dangerous voltage within the product enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
RMW8 Power cord protection The power cord should be positioned in a way it will not be stepped on or pinched by items placed upon or against it, paying particular attention to cable connected to the plugs, sockets and wall outlets. Cleaning: The unit can be cleaned with compressed air or with a soft damp cloth. Do not clean the unit with solvents such as trichloroethylene, thinners, alcohol, or other fluids with very strong volatility and flammability.
RMW8 IMPORTANT SAFETY INSTRUCTIONS: Install this unit following owner’s manual instructions. Do not install, connect or disconnect power supply when the unit is powered, to avoid electric shock. Do not open the unit: there are no user serviceable parts inside. If you detect any strong smell emanating from the unit, immediately turn it off and disconnect the AC power cord. Do not block the unit ventilation openings. Avoid using this unit in overload for a long period.
RMW8 Thank you for choosing this PROEL product and for your trust in our brand, synonymous of professionalism, accuracy, high quality and reliability. All our products are CE approved and designed for continuous use in professional systems. 2. Description The RMW8 Wireless Microphone system features 3 units: The RMW8 receiver, WMP handheld transmitter and WHL body pack transmitter. A carrying case is included.
RMW8 b) Rear Panel RMW8 6 5 4 3 2 1 1. UP / DOWN In manual selecting mode, use the Up key to scan the frequency presets from 0 to 99 and Down key from 99 to 0. 2. Menu Keep pressing the Menu key for 1,5 seconds , it comes to the SQ mode. 3. LOW MID HI This key controls the AF output Balanced level. Set the key to Low position for –12db output, Mid for –6db, High for 0db. 4. 6.3 Jack Mono Unbalanced audio output Use a jack mono 6.3 and a shielded unbalance cable. 5.
RMW8 d) Body Pack Transmitter WHL 1. Display LCD displays: antenna symbol (when TX and RX are couplet), operating frequency, charge battery level, CHANNEL, power transmission (PL), LOCK 2. CH/ON Pressing for one second to switch on the transmitter. The transmitter displays the current frequency, the battery charge level. Press again to pass in a cyclic mode the following functions: CHANNEL / PL / LOCK. To disable the transmitter press and keep pressing for one second 3.
RMW8 4. Operation a) Receiver RMW8 Squelch Control Enter SQUELCH mode pressing the MENU key, the symbol with the current level value is displayed: Number Squelch threshold 1 95,0 dB 2 91,7 dB 3 88,3 dB 4 85,0 dB 5 81,7 dB 6 78,3 dB 7 75,0 dB 8 71,7 dB 9 68,3 dB 10 65,0 dB AUDIO METER dB RF METER Select level using key UP and DOWN, confirm pressing with MEM key.
RMW8 Mute function Pressing the select key for more than one second will activate the mute function, the word Mute word displayed. Pressing SELECT again will deactivate the mute function. When MUTE function is active the transmitter does not transmit. Battery When batteries are exhausted, the battery level indicator will light. If rechargeable batteries are used, use AA 1,5V Battery. To re-charge the batteries, use battery charger (optional) and apply to the appropriate connector (see fig.3 ref.6).
RMW8 6. Frequency Table (798.000-827.000mhz) CH 0 CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH8 CH 9 CH 10 CH 11 798.125 798.325 798.525 798.725 798.925 799.125 799.325 799.525 799.725 799.925 800.125 800.325 CH 12 CH 13 CH 14 CH 15 CH 16 CH 17 CH 18 CH 19 CH 20 CH 21 CH 22 CH 23 800.525 800.725 800.925 801.125 801.325 801.525 801.725 801.925 802.125 802.325 802.525 802.725 CH 24 CH 25 CH 26 CH 27 CH 28 CH 28 CH 30 CH 31 CH 32 CH 33 CH 34 CH 35 802.
RMW8 MODEL Trasmission mode Frequency band: Frequency response: Frequency stability: T.H.D: Modulation mode RF Output power Dynamic Tone Frequency Max deviaton Battery Microphone type Dimensions (WxDxH) Weight WHP PLL Multi-channels, up 100 frequency preset for each frequency band UHF 798 ÷ 827MHz 50Hz - 15KHz (-3dB) 0,005% (-10°C - 50°C) < 0,8% 1KHZ FM (F3E) max 50mW (adjustable 3 levels) >100dB 30-33 KHz +/-35KHz “AA” type x 2 Hcm38 ( optional ) 66 mm. x 103 mm.
PROEL S.p.A. (World Headquarters - Factory) Via alla Ruenia 37/43 64027 Sant’Omero (Te) – Italy Tel: +39 0861 81241 Fax: +39 0861 887862 E-mail: info@proelgroup.com www.proelgroup.