User Manual

21
RMW10
Squelch Control
Enter SQUELCH mode pressing 5 times MENU key, SI symbol with the current level value is displayed:
Number
Squelch theresholdl
1
95,0 dB
2
91,7 dB
3
88,3 dB
4
85,0 dB
5
81,7 dB
6
78,3 dB
7
75,0 dB
8
71,7 dB
9
68,3 dB
10
65,0 dB
Select level using key UP and DO, confirm pressing with MEM key.
If the input signal is below the setting level, the receiver is muted .This eliminates background noise during pause time. Ensure to set
such level to avoid to eliminate the signal .
Transmitter WMP/WHP
Press for one second to switch on the Transmitter. Transmitter displays the current frequency, the battery charge level. Press newly to
pass in a cyclic mode to the following functions: CHANNEL - GROUP - PL - LOCK / UNLOCK. To disable the transmitter press and
keep pressing for one second.
Frequency selection
Enter CHANNEL mode pressing key CH/ON, CH symbol is displayed along with the current channel value. Using SELECT key to
select CHANNEL. Using key CH/ON GROUP mode is activated, the symbol GP is displayed with the current group value. Use
SELECT key for GROUP selection. Some seconds after the last key press, the display comes back to the main menu.
RF level Selection
Enter POWER mode pressing 3 times key CH/ON, Symbol PL and the current power value are displayed. Use SELECT key to select
the output power you need , 0 : the output power is 5dB ,1 : the output power is 10dB , 2 : the output power is 15dB . Some seconds
after the last key press, the display comes back to the main menu .
Lock Function
Enter Look/unlock mode pressing 4 times CH/ON key, Symbol look or unlock ( considering the setting selected) are displayed , Using
SELECT key to select the setting (look/unlock). Some seconds after the last key press, the display return the initial visualisation.
When the transmitter is blocked, it is possible to effect the functions scan. The display visualise the current setting without allowing the
setting modification: the sole available functions setting is : to power on, to switch off, to set MUTE and lock selection.
Mute function
Press for more than one second SELECT key, the MUTE function is activated, Mute word is displayed. Pressing newly SELECT
mute words disappears and MUTE function is disable. When MUTE function is active the transmitter does not transmit.
Battery
When batteries are exhausted, the battery level indicator will light. Replace or charge ( if rechargeable batteries are used ) .
Use AA 1,5V Battery. To re-charge the batteries, use battery charger ( optional) apply to the appropriate connector . Recharging time
is generally about 6 hours . During the re-charges operation, the battery level indicator is dynamic.