OPERATION
After you connected the effect to the mains, the fixture starts running. During the reset, the motors are
trimmed and the device is ready for use afterwards.
Each projector occupies 5 channels. To ensure that the control signals are properly directed to each
projector, the projector requires addressing. This is to be done for every single projector by changing
the DIP switches as set out in this table.
Please make sure that you don’t have any overlapping channels in order to control each projector
correctly and independently from any other fixture on the DMX data link. If two, three or more projector
is addressed similarly, they will work similarly.
After having addressed all projectors, you may now start operating these via your lighting controller.
NOTE:
After switching on, the projector will automatically detect whether DMX 512 data is received or not. If
the data is received, DMX-LED is lit. If there is no data received at the DMX-input, the DMX-LED is off.
This situation can occur if:
- the 3 PIN XLR plug is not connected with the input of the projector
- the controller is switched off or defective
- the cable or connector is defective
- the signal wires are swap in the input connector
DMX CONTROL CHANNELS
channel 1: macro
channel 2: red
channel 3: yellow
channel 4: blue
channel 5: green
INSTALLING/REPLACING THE LAMP
Warning Isolate electrically before re-lamping. The lamp shall be changed if it becomes damaged or
thermally deformed.
Caution: very hot lamp.
Only the halogen linear lamp 300W/500W 117mm are supported (PROEL PLLP300117 – PLLP500117)
Warning Installing any other lamp may damage the fixture!
- Disconnect the fixture from power and allow it to cool for 20 minutes.
- Remove 4 screws on the front side and open the lamp housing.
- Grasp the old lamp and slide it carefully out of the lamp holder.
- Insert new lamp.
- Clean the glass bulb and reflector with a cloth, particularly if your fingers touched the glass. A clean,
lint-free cloth wetted with alcohol is best.
- Gently close the lamp housing and screw 4 screws.