User Manual
R&D Department 
Testing Procedure 
From  PROEL R&D DEPT. 
To  PROEL SERVICE DEPT. 
Object  FLASH5A amplifier module - TESTING PROCEDURE 
Date  30/04/2014 
Instruments required: 
1) Sinusoidal audio signal generator 
2) 100MHz or more dual trace oscilloscope (scope) 
3) True RMS digital multimeter (DMM) with dBu scale 
4) 250W or more Variac transformer with 0-250 Vac range (230V european version) 
 or with 0-140 Vac range (120V US version) 
5) 4 Ω 100W or more resistive load 
6) 8 Ω 50W or more resistive load 
7) Music and pink noise signal generator (CD player) 
 IMPORTANT: The oscilloscope must be insulated from the earth ground. 
1. Set up 
- Check the correct earth main connection on the rear surface of the front panel. 
- Check the insulation between the heat sink and the case of IC4, IC5 and IC3. 
- Set the LINE LEVEL control full clockwise. 
- Set the NEARFIELD/MIDFIELD button in NEARFIELD position. 
- Switch OFF the amplifier module. 
2. Low amplifier check 
- Connect the mains of amplifier module to VARIAC and set it at zero AC voltage. 
- Connect the scope CH1 GND clip to P8 black wire/faston (GND), scope CH1 probe tip to P6 red wire/faston 
(LOW OUT) and scope CH2 probe tip to P10 black wire/faston (HIGH OUT). 
- Switch ON the amplifier module. 
- Increase slowly the VARIAC voltage up to the nominal value (230Vac or 120Vac). 
- Check the transformer secondary voltages with DMM (without signal on input): 
52 ±2 Vac  between red wire 
32 ±2 Vac  between yellow wire 
-  Using DMM check also the +15Vdc / -15Vdc supplies on relative voltage regulator outputs (IC4 & IC5 
devices). 
- Connect the signal generator to LINE INPUT (XLR/JACK socket) and set it at 100 Hz, -10 dBu. 
- Verify that CH1 (LOW OUT) signal is 30V ±6 Vpp. 
- Check of SIGNAL/LIMIT LED function, moving the volume potentiometer of the amplifier; 
when the output signal is < 2 Vpp the led must be OFF 
when the output signal is > 2 Vpp, the led must be GREEN. 
- Rotate the volume potentiometer knob fully clockwise. 
- Set the signal generator at 0 dBu. 
- Connect the 4 Ω load resistor at LOW OUT and verify that the signal is symmetrical refer to GND, without 
detectable distortion and oscillation. 
 1 