User manual

EDITING USER PRESETS
If you connect the CX15A to a PC, using PRONET Control So ware you can edit the user presets. In par cular, the user preset no.
4-U can be loaded also from the unit’s control panel without the need to connect again the loudspeaker to PRONET.
Here below there is a a brief explana on about how to edit the main DSP parameters.
In/Out - Level: adjusts the input level gain in the range of -30 ÷ +6 dB (this is a digital control a er the A/D converter).
In/Out - Input Meter: shows the input level signal a er the A/D converter. Green LED indicates the normal opera ng level before nominal input
sensi vity (+4 dBu), yellow LED indicates that the signal exceeds the nominal sensi vity, red LED indicates digital clipping and must be avoided.
In/Out - Compressor/Limiter: this is a compressor/limiter for the input signal, that can be used to increase loudness and transparency (for the
best results, we recommend to not change the factory se ngs).
In/Out - Output Level Trim: use these controls in you want to trim nely the level of woofer and HF driver.
In/Out - MUTE: these bu ons can be used to switch o the woofer or the HF driver in order to check the system.
In/Out - Input Delay: edit this box to apply a delay to the speaker, to be used pically if you need to align in me the speaker to another sound
source. Note: a delay higher than 10 mS (3 m) is easily audible and it can be annoying to singers and musicians.
PEQ - EQ1-5: 5-band full parametric EQ. Note: CX15A is already opƟ mized for the best performance for wedge monitoring, so we suggest to make
only small adjustments.
Setup - Device Name: here you can assign a unique name at the unit (twelve characters are available).
Setup - Device Group: here you assign the unit to a group, so when the LINK func on on PRONET so ware is ac vated, you can automa cally set
the same parameters to all the units assigned to the same group.