Product manual

the types of events for which the switch will send these
messages. In all cases, the switch will send all messages
resulting from thresholds, to the network management
station that explicitly set each threshold. The levels
specied on this screen correspond only to the traps set
for event log messages, not to those set for thresholds.
You can specify up to 10 trap receivers (network management
stations).
Parameters:
o COMMUNITY-STR - SNMP community string.
o IP-ADDR - IP address of SNMP notication host.
o [none|all|not-info|critical|debug] - The level of Switch
events that will generate a trap to be sent: none - send no log
message; all - send all log messages; not-info - send each log
message that is not informational-only; critical - send
critical-level log messages; debug (reserved for Internal use).
o [informs [retries RETRY-COUNT] [timeout TIMEOUT]] If 'informs'
is added to the command, informs rather than traps are sent.
Retries denes the number of retries to attempt when a response
is not received. The default is 3. Timeout denes the interval
between retries, measured in seconds. The default is 15 seconds.
Next Available Options:
address -- IP address of SNMP notification host. (IP-ADDR) (p. 528)
address_ipv6 -- IPv6 address of SNMP notification host. (IPV6-ADDR) (p. 528)
community -- Name of the SNMP community (up to 32 characters). (ASCII-STR) (p. 528)
informs -- Specify if informs will be sent, rather than notifications.(p. 531)
events < None | Debug | All | ... > -- (p. 529)
hpSwitchAuthMIB
snmp-server mib hpSwitchAuthMIB
Usage: snmp-server mib hpSwitchAuthMIB <excluded|included>
Description: Enable/Disable SNMP support for the hpSwitchAuthentication MIB.
When the MIB access is enabled, Manager read/write access
to the MIB is permitted. Operator read/write access to the MIB
is always denied. For security reasons, network administrators
are encouraged to disable SNMPV2c before using the MIB.
Next Available Options:
included -- Enables SNMP support for the hpSwitchAuthentication MIB.(p. 530)
excluded -- Disables SNMP support for the hpSwitchAuthentication MIB.(p. 529)
included
snmp-server mib hpSwitchAuthMIB included
530© 2008 Hewlett-Packard Development Company, L.P.
snmp-serverCommand Line Interface Reference Guide