Product manual

redundancy
OVERVIEW
Category:
configPrimary context:
Related Commands
Usage: redundancy switchover
redundancy active-management < management-module1 |
management-module2 |
standby>
[no]redundancy management-module
redundancy fabric-module <<1|2> <enable|disable>>
Description: Redundancy conguration for management and fabric modules.
The rst version of the command causes the switch to
immediately switchover to the standby management module.
The second version of the command makes the module specied
an active management module for next boot. This command
will fail if the other module is in a failed state.
The third version of the command enables/disables
redundant management. The current 'active' management module
will continue to be the 'active' management module on boot,
unless the user uses the 'redundancy active-management ...'
command to change to the other module.
The fourth version of the command enables/disables the fabric
modules.
NOTES
Multiple Contexts
This command also is available in the manager context.
COMMAND STRUCTURE
redundancy active-management < management-module1 | management-module2 | standby >
-- Specify the management module that will be active for next boot. (NUMBER) (p. 400)
redundancy fabric-module < 1 | 2 > -- Enable/Disable fabric modules. (NUMBER) (p. 401)
disable -- Disable the fabric module. (p. 401)
enable -- Enable the fabric module. (p. 401)
[no] redundancy management-module -- Enable/Disable redundant management. (p. 401)
redundancy switchover -- Switchover to the standby management module. (p. 401)
COMMAND DETAILS
management-module (p. 401)enable (p. 401)active-management (p. 400)
switchover (p. 401)fabric-module (p. 401)disable (p. 401)
active-management
redundancy active-management < management-module1 | management-module2 | standby >
Specify the management module that will be active for next boot.
400© 2008 Hewlett-Packard Development Company, L.P.