Specifications
Table Of Contents
- HP 8200 zl Switches
- Installation and Getting Started Guide
- Contents
- Introducing the HP 8200 zl Switches
- Installing the HP 8200 zl Switches
- Included Parts
- Power Cords
- Installation Procedures
- Summary
- Installation Precautions
- 1. Prepare the Installation Site
- 2. Mount the Switch Chassis
- 3. Install the Switch Modules
- 4. Install the Power Supplies
- 5. Verify the Switch Passes Self Test
- 6. Install the Grounding Wire
- 7. Connect the Switch to a Power Source
- 8. (Optional) Connect a Power Supply Shelf to the switch
- 9. Connect the Network Devices
- 10. (Optional) Connect a Console to the Switch
- Hot Swapping Switch Modules
- Example Network Topologies
- Getting Started With Switch Configuration
- Replacing Components
- Troubleshooting
- Specifications
- Switch Ports and Network Cables
- Cabling and Technology Information Specifications
- Mode Conditioning Patch Cord
- Twisted-Pair Cable/Connector Pin-Outs
- Safety and Regulatory Statements
- Recycle Statements
- Index
- Installation and Getting Started Guide

1-10
Introducing the HP 8200 zl Switches
Front of the 8200 zl Switches
Introducing the HP 8200 zl
Switches
Blinking
orange
1
Blinking
orange
2
Internal PoE fault.
External load fault or denied PoE power.
Tmp
(green/orange)
Off Switch temperature is normal.
Blinking
1
An over temperature condition has been detected.
Fan
(green/orange)
On green The cooling fans are operating normally.
Blinking
orange
1
One or more of the cooling fans have failed. The switch Fault LED will be blinking
simultaneously.
Internal Power 1-4
(green/orange -
numbers
corresponding to
the power supply
positions)
On green A power supply is installed in the position in the back of the switch corresponding
to the number, and the supply is plugged in to an active AC power source. As
shipped, the switch has a single power supply in position 1.
Off A power supply is not installed in the position corresponding to the number.
Blinking
orange
1
The power supply installed in the position corresponding to the number is not
plugged in to an active AC power source, or has experienced a fault. The switch
Fault LED will be blinking simultaneously.
EPS (1 and 2)
(green/orange)
On green
Off
An External Power Supply is connected.
No External Power Supply is connected.
Blinking
orange
1
The External Power Supply has a fault, or is connected but not plugged into AC
power.
Fabric Modules
(1 and 2)
(green/orange)
On green
Off
A Fabric Module is installed and functioning correctly.
A Fabric Module is not installed or has failed.
Blinking
orange
1
The Fabric Module has a fault.
The switch Fault LED will be blinking simultaneously.
LED Mode Select
(5 green LEDs)
Act Indicates that the port Mode LEDs are displaying network activity information.
FDx Indicates that the port Mode LEDs are lit for ports that are in Full Duplex Mode.
PoE Indicates which ports are supplying PoE power.
• If the Mode LED is on the port is providing PoE power.
• If the Mode LED is off the port is not providing PoE power.
• If the Link LED is on the port is enabled for PoE.
• If the Link LED is off the port is disabled for PoE.
• If the Link LED is blinking, the port has an error or the port is denied power due
to insufficient power.
Spd Indicates the Port LEDs are displaying the connection speed at which each port
is operating:
• if the Port LED is off, the port is operating at 10 Mbps
• if the Port LED is blinking, the port is operating at 100 Mbps
• if the Port LED is on continuously, the port is operating at 1000 Mbps
Usr Reserved for future development