Specifications
Table Of Contents
- HP 8200 zl Switches
- Installation and Getting Started Guide
- Contents
- Introducing the HP 8200 zl Switches
- Installing the HP 8200 zl Switches
- Included Parts
- Power Cords
- Installation Procedures
- Summary
- Installation Precautions
- 1. Prepare the Installation Site
- 2. Mount the Switch Chassis
- 3. Install the Switch Modules
- 4. Install the Power Supplies
- 5. Verify the Switch Passes Self Test
- 6. Install the Grounding Wire
- 7. Connect the Switch to a Power Source
- 8. (Optional) Connect a Power Supply Shelf to the switch
- 9. Connect the Network Devices
- 10. (Optional) Connect a Console to the Switch
- Hot Swapping Switch Modules
- Example Network Topologies
- Getting Started With Switch Configuration
- Replacing Components
- Troubleshooting
- Specifications
- Switch Ports and Network Cables
- Cabling and Technology Information Specifications
- Mode Conditioning Patch Cord
- Twisted-Pair Cable/Connector Pin-Outs
- Safety and Regulatory Statements
- Recycle Statements
- Index
- Installation and Getting Started Guide

1-7
Introducing the HP 8200 zl Switches
Front of the 8200 zl Switches
Introducing the HP 8200 zl
Switches
Switch and Module LEDs
As described in the following tables, there are LEDs on the switch chassis and
on the switch modules that keep you informed of the status of the switch and
the network connections.
Power
and Fault
LEDs
Locator LED
Figure 1-5. Switch Chassis LEDs
Table 1-2. Switch Chassis LEDs
LEDs State Meaning
Power
(green)
On The switch is receiving power.
Off The switch is NOT receiving power.
Fault
(orange)
Off The normal state; indicates that there are no fault conditions on the switch.
Blinking
1
A fault has occurred on the switch, one of the switch modules, an individual port, a power
supply, or a fan. The Status LED for the module or other device with the fault will flash
simultaneously.
On On briefly at the beginning of switch self test after the switch is powered on or reset. If on
for a prolonged time, the switch has encountered a fatal hardware failure, or has failed its
self test. See chapter 5, “T
roubleshooting” for more information.
Locator
(blue)
On
Blinking
Off
The Locator LED is used to locate a specific chassis in a area full of chassis. The LED can
be set to be on solid or blink for a specified number of minutes (1-1440). The default is 30
minutes. Use the command “chassislocate”.
1
The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
2
The blinking behavior is an on/off cycle once every 0.5 seconds, approximately.