System information

Traffic/Security Filters
Filter Types and Operation
Filter Limits
The switch accepts up to 101 static filters. These limitations apply:
Source-port filters:
Series 5300xl: Up to 78
Series 3400cl: One per port or port trunk
Multicast filters (5300xl only): up to 16
Protocol filters (5300xl only): up to 7
Using Port Trunks with Filters
The switch manages a port trunk as a single source or destination for source-
port filtering. If you configure a port for filtering before adding it to a port
trunk, the port retains the filter configuration, but suspends the filtering action
while a member of the trunk. If you want a trunk to perform filtering, first
configure the trunk, then configure the trunk for filtering. Refer to
“Config-
uring a Filter on a Port Trunk” on page 8-10.
Filter Types and Operation
Table 8-1. Filter Types and Criteria
Static Filter
Type
Selection Criteria
Source-Port Inbound traffic from a designated, physical source-port will be forwarded or
dropped on a per-port (destination) basis.
Multicast Inbound traffic having a specified multicast MAC address will be forwarded to
(5300xl only) outbound ports (the default) or dropped on a per-port (destination) basis.
Protocol
(5300xl only)
Inbound traffic having the selected frame (protocol) type will be forwarded or
dropped on a per-port (destination) basis.
8-3