Installation guide
15
Known Issues
Release Y.11.01
Known Issues
Release Y.11.01
The following problems are known issues in release Y.11.01.
■ RADIUS/Web Management (PR_1000811781) — When the user attempts RADIUS
authentication to the Web Management Interface, the switch may crash with a message
similar to the following.
TLB Miss: Virtual Addr=0x0024c904 IP=0x0024c904 Task='tHttpd'
Task ID=0x81e46eb0 fp:0x00000000 sp:0x81e46d70 ra:0x0024c904 sr:0x1000fc01
Release Y.11.03
The following problems are known issues in release Y.11.03.
■ Menu (PR_0000003963) — In the TELNET menu interface, under Switch Configuration -
> Port/Trunk Settings, the BX transceivers may be displayed as 100GEN or 1000GEN in the
Type column, rather than 100BX-U, 100BX-D, 1000BX-U, or 1000BX-D.
■ BX Mini-GBIC/Transceiver (PR_0000010525) — A 100BX transceiver or 1000BX mini-
GBIC may fail self test under certain circumstances, such as insertion of an SFP in both port
49 and port 50 at exactly the same time. Workaround: re-insertion of the SFP device should
allow proper initialization and function.
Release Y.11.12
The following problem is a known issue in release Y.11.12.
■ Crash (PR_0000041599) — The presence of snmp-server CLI commands in an uploaded
configuration file may cause the switch to reboot unexpectedly with one of the following
crash messages.
'TLB Miss: Virtual Addr=0x00000000 IP=0x80618fc0 Task= 'mftTask''
PPC Bus Error exception vector 0x300: Stack-frame=0x0124cc40
HW Addr=0x025aa1cc IP=0x00538808 Task='mftTask' Task ID=0x124dcb0
fp: 0x012d5c30 sp:0x0124cd00 lr:0