Technical data

Procon
. F T P
The  ue terminal of the Procon , ,  &  boilers will plume water vapour, heavily and care must be taken
when selecting the terminal position to ensure that a “nuisance situation is not created.
Where the  ue terminal discharges within 2 metres of ground or any upper part of the building where
people have general access, i.e. balcony level, etc., a terminal guard MUST be  tted to prevent the terminal
from being touched.
Minimum Distance
All Dimensions are in millimeters, See Fig .
Dimension Description
Minimum
Distance
Dimension Description
Minimum
Distance
A
Directly below an opening,
air brick, window, etc.
 J
From an opening, door,
window, etc., in a car port

B
Below gutters, soil pipes,
drain pipes, etc.
 K
Vertically from a terminal on
the same wall.

C Below eaves  L
Horizontally from a terminal
on the same wall.

D
Below balconies, car port
roof, etc.
 M
Above an opening, window,
etc.

E
Vertically from soil pipes,
drain pipes, etc.
 N
Horizontally to an opening,
window, etc.

F
From internal or external
corners.
 P
Above a level roof (base of
terminal).

G
Above ground, intersecting
roof, balcony level, etc.
 Q
Q From adjacent wall (edge
of terminal).

H
From a surface facing the
terminal.
 R
From adjacent opening
window.

I
From a terminal facing the
terminal.
 S From any other  ue terminal. 
Note: Dimensions highlighted in BOLD are not recommended locations.
Fig . – Minimum Clearances
