Installation manual
www.usaprocom.com
17200088-01A
OPERATION
THERMOSTAT CONTROL OPERATION
The thermostatic control used on this model differs from standard thermostats. You set standard 
thermostats to a specic temperature such as 72 degrees.  The thermostat used on this heater 
senses the room temperature. At times the room may exceed the set temperature. If so, the 
burner will shut off. The burner will cycle back on when room temperature drops below the set 
temperature. The control knob can be set to any comfort level between Low (1) and HIGH (5).
Shutting Off Heater
Turn  control  knob  clockwise    to  the 
OFF position.
Shutting Off Burner Only (pilot 
stays lit )
Turn  control  knob  clockwise    to  the 
PILOT position.
1.  Remove  2  screws  securing  screen  to 
stove. Carefully lift and pull screen forward 
to remove.
2.  Follow steps 1 through 5 under Lighting 
Instructions, page 16.
3.  With control knob in PILOT position, strike 
match, and hold near pilot. Press in control 
knob; pilot should light.
4.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob. 
5.  Make sure the heater screen is in place 
before operating heater.
TO TURN OFF GAS TO APPLIANCE
MANUAL LIGHTING PROCEDURE
Note: If pilot does not stay lit, refer to 
Troubleshooting, page 21. Also contact a 
qualied service technician or gas supplier 
for repairs. Until repairs are made, light 
pilot with match. To light pilot with match, 
see Manual Lighting Procedure.
7.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob.
  Note: If pilot goes out, repeat steps 3 
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before 
lighting pilot again.
8.  Turn control knob counterclockwise   
to  the  desired  heating  level.  The  main 
burner  should  light.  Set  control  knob  to 
any heat level between HI (5) and LO (1).
  Note: Please wait one minute after shut-
ting off replace to allow the control valve 
to reset before starting again.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
  WARNING:  If  input  gas 
type is NG, make sure NG pilot 
burner ignites. If input gas type 
is LP, make sure LP pilot burner 
ignites.
Figure 18 - Pilot
Pilot Air 
Inlet Hole
Natural Gas 
Burner
Propane/LP 
Gas Burner