Specifications

13
Figure 15- Manual Control
Push in gas control knob slightly
and turn clockwise to OFF.
Do not use force. NOTE: Wait one
(1) minute with control knob in OFF
position before operating heater.
9. When electric power is available
and elelectronic operation is
desired, turn clockwise to
OFF positon for one minute. Then
pressdown knob and rotate
clockwise to ELECTRIC
position. Do not operate between
locked positions.
1. Remove lower front panel.
2. Follow steps 1 through 5 under
Manual Operatting
Instructions on page 12.
3. With control knob pressed in, strike
match. Hold match to pilot until pilot
lights.
MANUAL LIGHTING
PROCEDURE
INSPECTING BURNER
Check pilot flame pattern and burner
flame pattern often.
MANUAL OPERATING
INSTRUCTIONS
continued
4. Keep control knob pressed in for 30
seconds after lighting pilot.
5. Rotate counterclockwise to ON po-
sition to light burner. Do not oper-
ate between looked positions.
4. Replace lower front panel.
TO TURN OFF GAS TO
APPLIANCE
(Match Light)
l turn heater off (see page 11)
l see Troubleshooting, pages 17
through 19.
Figure 16- Correct Pilot Flame
Pattern
BURNER FLAME PATTERN
Figure 18 shows a correct burner
flame pattern. Figure 19 shows an
incorrect burner flame pattern. If
burner flame pattem is incorrect,
as shown in Figure 19.
l turn heater off (see page 11 ).
l see Troubleshooting. pages 17
through 19.
PILOT FLAME PATTERN
Figure 16 shows a correct pilot flame
pattern. The incorrect pilot flame is
not touching hermocouple. This will
cause the thermocouple to cool.
When the thermocouple cools, the
healer will shut down. If pilot flame
pattern is incorrect, as shown in Fig-
ure 17.
Figure 17 - Incorrect Pilot Flame
Pattern
Figure 18 - Correct Burner Flame
Pattern
Figure 19 - Incorrect Burner
Flame Pattern