Specifications
12
OPERATING YOUR HEATER
continued
AUTO ON: With burner off, press
TIMER button. Then press or to
change to the scheduled time, then
press the TIMER button again, the
TIMER starts timing and the TIMER
will flash. Burner will automatically
come on at the set time.
SETTING TIMER
AUTO OFF: With burner operating,
press TIMER button. Then press or
to change to the scheduled time,
then press the TIMER button again,
the TIMER starts timing and the
TIMER will flash. Burner will automati-
cally shut off at the desired time.
LOCKING TOUCH-PAD
(childproof)
A. Key-press locking: Press LOCK
button on the operating panel,
a symbol will appear on the LCD.
B. Key-press unlocking: Press ,
then press LOCK button to unlock.
1.Press the IGN/OFF button on the
touch pad.
2.Set the ON/OFF switch to OFF posi-
tion on top panel.
If the manual control knob points to
ELECTRIC position, press in the con-
trol knob and turn counter clockwise
to OFF position.
4. Wait five (5) minutes to clear any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation on page11. If you do not
smell gas, go to the next step.
5. Push in gas control knob slightly
and turn counterclockwise to
PILOT/IGN and depress for five(5)
seconds. NOTE:The first time the
heater is operated after connecting
the gas supply, the control knob
should be depressed for about
thirty(30) seconds. This will allow
air to exit the gas system.
6. With control knob pressed, push
and release ignitor button. This
will light the pilot. If needed, keep
pressing ignitor button until pilot
lights.
7. Keep control knob depressed for
ten (10) seconds after lighting
pilot. If pilot goes out, repeat steps
5,6 and 7.
8. Rotate counterclockwise to
ON position to light burner. Do not
operate between locked positions.
NOTE: Wait one minute to light
again after shutting off heater.
MANUAL OPERATING
INSTRUCTIONS
TO TURN OFF GAS TO
HEATER
MAN: Blower operates continuously.
OPERATING BLOWER
Press BLOWER button, for desired
blower operation.
OFF: Blower is off.
AUTO: Blower will come on several
minutes after burner comes on and
will go off several minutes after burner
goes off.
1. STOP! Read the safety information
on page11 before lighting.
3. Remove round access door of right
side panel. Push in control knob
slightly and turn clockwise to the
OFF position.
We provide the manual control
system just in case of power
shortage. Install battery for Manual
Ignitor:
1. Unscrew the ignitor cap.
2. Insert a AAA type battery with its an-
ode (“+”) pointing out.
3. Screw the ignitor back cap.
Note: We recommend that the battery
be taken out of the ignitor when the
power supply gets right.
2. Check that gas supply to the heater
is on.
Control Knob
Ignitor Button