Product specifications

9
Figure 4 - Mouting clearances as
viewed from front of heater (inches)
WARNING: Never install the heater
in a bedroom or bathroom
in a recreational vehicle
where curtains, furniture, clothing, or other ammable objects
are less than 36 inches from the front, top, or sides of the heater
in high trafc areas
in windy or drafty areas
WARNING: Maintain the minimum clearances shown in Figure
4. If you can, provide greater clearances from oor, ceiling, and
joining wall.
CAUTION: This heater creates warm air currents. These current
move heat to wall surfaces next to heater. Installing heater next to
vinyl or cloth wall coverings or operating heater where impurities
(such as tobacco smoke, aromatic candles, cleaning uids,
Check Gas Type
Be sure your gas supply is right for your heater. Otherwise, call dealer where you bought the heater for
proper type heater.
Clearances To Combustibles
Carefully follow the instructions below. This heater is a freestanding unit designed to be mounted on a wall or
set directly on the oor.
WARNING:
Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from
oor, ceiling, and joining wall.
LOCATING HEATER
This heater is designed to be mounted on a wall. For convenience and efciency, install heater:
where there is easy access for operation, inspection, and service.
in the coldest part of room.
INSTALLING THERMOSTAT SENSING BULB
(ONLY FOR ML/N200TBH & ML/N300TBH)
1. Pull out the sensing bulb from the two clips located in the
shipping position. There is no need to take out the two bulb clips.
2. Take out the bulb clip from the hardware package and insert
it into the square hole. Then insert the sensing bulb into the
bulb clip (see Figure 5).
Figure 5 - Moving Thermo-
stat Sensing Bulb
FASTENING HEATER TO WALL
Mounting Bracket
The mounting bracket is located on back panel of heater (see Figure 6).
It has been taped there for shipping. Remove mounting bracket from
back panel.
Removing Front Panel of Heater
1. Remove 4 screws - 2 screws on each side of the front panel.
2. Pull front panel forward.
3. Replace front panel when completed, using the screws removed.
Figure 6 - Mounting Bracket Location
oil or kerosene lamps, etc.) in the air exist may discolor walls.