8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control.
knob to any heat level between 1 and 5.
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
THERMOSTAT CONTROL OPERATION (ONLY FOR ML/N200TBH & ML/N300TBH)
The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn
on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may
exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature
drops below the set temperature. The control knob can be set to any comfort level between 1 and 5.
Note: The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not al-
ways agree with room temperature (depending on housing construction, installation location, room size, open air
temperature, etc). Frequent use of your heater will let you determine your own comfort levels.
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise to the OFF position.
Shutting Off Burner Only (pilot stays lit )
Turn control knob clockwise to the PILOT position.
MANUAL LIGHTING PROCEDURE
1. Remove front panel.
2. Follow steps 1 through 5 under “Lighting Instructions” on page 14.
3. With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Fol
-
low step 8 under “Lighting Instructions” on page 14.
5. Replace front panel.
Figure 17 - Control Knob in the
OFF Position
Figure 18 - Pilot