Specifications
12
OPERATING YOUR HEATER
continued
AUTO ON: With burner off, press
TIMER button. Then press or to
change to the scheduled time, then
press the TIMER button again, the
TIMER starts timing and the TIMER
will flash. Burner will automatically
come on at the set time.
SETTING TIMER
AUTO OFF: With burner operating,
press TIMER button. Then press
or to change to the scheduled
time, then press the TIMER button
again, the TIMER starts timing and
the TIMER will flash. Burner will
automatically shut off at the desired
time.
LOCKING TOUCH-PAD
(childproof)
A. Key-press locking: Press LOCK
button on the operating panel,
a symbol will appear on the
LCD.
B. Key-press unlocking: Press ,
then press LOCK button to unlock.
1.Press the IGN/OFF button on the
touch pad.
2.Set the ON/OFF switch to OFF
position on top panel.
IF NO ELECTRIC POWER IS
AVAILABLE, HEATER CAN BE OPER-
ATED MANUALLY
If the manual control knob points to
ELECTRIC position, press in the
control knob and turn counter clock-
wise to OFF position.
4. Wait five (5) minutes to clear any
gas. Then smell for gas, includ-
ing near the floor. If you smell
gas, STOP! Follow “B” in the
safety information on page11. If
you do not smell gas, go to the
next step.
5. Push in gas control knob slightly
and turn counterclockwise to
PILOT/IGN and depress for five(5)
seconds. NOTE: The first time the
heater is operated after connect-
ing the gas supply, the control
knob should be depressed for
about thirty(30) seconds. This will
allow air to exit the gas system.
6. With control knob pressed, push
and release ignitor button. This
will light the pilot. If needed, keep
pressing ignitor button until pilot
lights.
7. Keep control knob depressed for
ten (10) seconds after lighting
pilot. If pilot goes out, repeat
steps 5,6 and 7.
8. Rotate counterclockwise to
ON position to light burner. Do not
operate between locked positions.
NOTE: Wait one minute to light
again after shutting off heater.
MANUAL OPERATING
INSTRUCTIONS
TO TURN OFF GAS TO
HEATER
MAN: Blower operates continuously.
OPERATING BLOWER
Press BLOWER button, for desired
burner operation.
OFF: Blower is off.
AUTO: Blower will come on several
minutes after burner comes on and
will go off several minutes after
burner goes off.
1. STOP! Read the safety infor-
mation on page11 before lighting.
2. Check that gas supply to the
3. Remove round access door of
right side panel. Push in control
knob slightly and turn clockwise
to the OFF position.
heater is on.
We provide the manual control sys-
tem just in case of power shortage.
Install battery for Manual Ignitor:
1. Unscrew the ignitor cap.
2. Insert a AAA type battery with its
anode (“+”) pointing out.
3.Screw the ignitor back cap.
Note: We recommend that the battery
be taken out of the ignitor when the
power supply gets right.
Control Knob