Installation manual
Table Of Contents
- Safety
- Specifications
- Qualified Installing Agency
- Product Features
- Local Codes
- Preparing For Installation
- Unpacking
- Water Vapor: A By-Product Of Unvented Room Heaters
- Air For Combustion and Ventilation
- Installation
- Operation
- Inspecting Heater
- Care And Maintenance
- Troubleshooting
- Parts
- Replacement Parts
- Accessories
- Service Hints
- Technical Service
- Warranty
- 200000-01B Spn.pdf
- Seguridad
- Especificaciones
- Agencia de Instalación Calificada
- Características del Producto
- Normas Locales
- Preparación Para la Instalación
- Desempaque
- Vapor De Agua: Un Producto Derivado de Los Calentadores de Habitación Sin Ventilación
- Aire para combustión y ventilación
- Instalación
- Funcionamiento
- Inspección del calentador
- Cuidado y mantenimiento
- Solución de problemas
- Piezas de repuesto
- Accesorios
- Consejos para servicio
- Servicio técnico
- Piezas
- Garantía

www.usaprocom.com
21200000-01B
1/2 Glass
Height
1/2 Glass
Height
Yellow
Tipping
1/2 Glass
Height
1/2 Glass
Height
Yellow
Tipping
INSPECTING HEATER
Figure 22 shows a correct pilot ame pattern.
Figure 23 shows an incorrect pilot ame pat-
tern. The incorrect pilot ame is not touching
the thermocouple. This will cause the ther-
mocouple to cool, which shuts the heater off.
If pilot ame pattern is incorrect, as shown
in Figure 23
• turn heater off (see To Turn Off Gas to Ap-
pliance, page 19 or 20)
• see Troubleshooting pages 23 through 25.
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If the burner ame
pattern shows yellow tipping,
follow instructions below.
Figure 22 - Correct Pilot Flame Pattern
Figure 23 - Incorrect Pilot Flame Pattern
Figure 24 - Correct Burner Flame Pattern Figure 25 - Incorrect Burner Flame Pattern
IMPORTANT: Owner’s should check pilot ame pattern and burner ame pattern often.
Incorrect ame patterns indicate the need for cleaning (see Care and Maintenance,
page 22) or service.
WARNING: Only a qualied service person should service and
repair heater. This includes maintenance requiring replacement or
alteration of components.
PILOT FLAME PATTERN
Notice: Do not mistake orange ames with
yellow tipping. Dirt or other ne particles enter
the heater and burn causing brief patches of
orange ame.
BURNER FLAME PATTERN
Figure 23 shows a correct burner ame pat-
tern. Figure 24 shows an incorrect burner
ame pattern. The incorrect burner ame
pattern shows yellow tipping of the ame. It
also shows the ame higher than 1/2 the heat
shield height.
If burner ame pattern is incorrect, as shown
in Figure 24
• turn heater off (see To Turn Off Gas to Ap-
pliance, page 19 or 20)