3. Rotate and close cover over fuel selection device and reinstall screw.
4. Remove steel or metal hex plug (with wrench provided) from natural gas inlet of regulator and install into LP inlet of
regulator, use thread sealant to assure there are no leaks.
For changing from natural gas supply to propane supply
1. Remove bottom screw from cover plate, see figure 8, and rotate to expose fuel selection device.
2. For PROPANE GAS, press in knob using a flat screw driver with a blade the width of a quarter and turn knob
counterclockwise until the knob locks into the LP position (see Figure 10). Fuel selection device must be locked
into either the LP position or the NG position.
3. Rotate and close cover over fuel selection device and reinstall screw.
4. Remove hex plug from LP gas inlet of regulator and install into NG inlet of regulator, use thread sealant to assure
there are no leaks.
Figure 8
Figure 9