Use and Care Manual

www.usaprocom.com
160448-01C6
1. Provide propane supply system (see
Propane Supply, page 5).
2. Connect POL tting on hose/regulator
assembly to propane tank(s). Turn POL
tting counterclockwise into threads on
tank. Tighten rmly using wrench.
IMPORTANT: Position regulator so that
hose leaving the regulator is in a hori-
zontal position (see Figure 3). This places
the regulator vent in the proper position to
protect it from the weather.
3. Connect hose to valve inlet (see Figure
4). Tighten rmly using a wrench.
IMPORTANT: Use extra hose or piping
if needed. Install extra hose or piping
between hose/regulator assembly and
propane tank. You must use the regulator
supplied with heater.
4. Open propane supply valve on propane
tank(s) slowly. Note: If not opened slowly,
excess-ow check valve on propane tank
will stop gas ow. You may hear a click
from the excess-ow check valve closing.
If this happens, reset the excess-ow
check valve by closing propane supply
valve and open again slowly.
Figure 4 - Hose and Inlet Connector
Hose
Inlet Connector
INSTALLATION
Figure 3 - Regulator Position
Figure 5 - Attaching Base Feet
Model PCFA40
Figure 6 - Adjusting Heater Height
Model PCFA60V
Propane
Tank
Propane Supply
Valve
Regulator
Support
Bracket
Fastener
Hose
POL
Fitting
5. Check all connections for leaks. Apply
mixture of liquid soap and water to gas
joints. Bubbles forming show a leak that
must be corrected.
6. Close propane supply valve.
BASE FEET (PCFA40 ONLY)
1. Locate 2 rubber feet and 2 screws in
hardware package.
2. Attach to bottom of base as shown in
Figure 5.
SUPPORT BRACKET
(PCFA60V ONLY)
To adjust the height of the front of the heater,
unscrew the fastener securing the support
bracket. Adjust bracket to desired height and
tighten fastener.