Use and Care Manual

www.usaprocom.com
160448-01C2
SPECIFICATIONS
Model PCFA40 PCFA60V
Output Rating 40,000 BTU/Hr 60,000 BTU/Hr
Fuel Consumption/Hour 0.44 gal (1.65 liter),
1.86 lb (0.84 kg)
0.66 gal (2.48 liter),
2.78 lb (1.26 kg)
Manifold Pressure 9.7 PSI 19.8 PSI
Ignition Manual Piezo Electric Spark
Fuel Propane Vapor
Supply Pressure To Regulator Minimum* 20 psi Minimum* 25 psi
Maximum Tank Pressure or 200 psi
Regulator Outlet Pressure 10 PSI 20 PSI
Motor 2000 RPM 2900 RPM
Electric Input 120 Volt/60 Hertz/1 Phase
Amperage 0.6
Temperature Range for Heater Operation 0° F to 85° F** (-17° C to 29.4° C**)
* For purposes of input adjustment
** When running heater in temperatures above 85° F (29.44° C), high internal temperatures may cause
thermal limit device to shut down heater.
TABLE OF CONTENTS
Specications ............................................ 2
Safety ........................................................ 3
Unpacking.................................................. 4
Product Identication ................................. 4
Theory of Operation................................... 5
Propane Supply ......................................... 5
Installation ................................................. 5
Ventilation .................................................. 7
Operation ................................................... 7
Storage ...................................................... 8
Maintenance .............................................. 8
Service Procedures ................................... 9
Troubleshooting ........................................11
Parts ........................................................ 12
Wiring Diagram ........................................ 16
Replacement Parts .................................. 16
Accessories ............................................. 17
Technical Services ................................... 17