Model # Orice Orice #
SSEAV18RP G 18
SSEAV24RP H 24
SSWV24RP H 24
SSWV30RP I 30
The number stamped on orices correspond
to each respective size log set as indicated by
model numbers as shown in table below.
For an 18 in. or 30 in. log set, use a 10 mm
socket or nut driver to remove the orice from the
propane/LP burner air mixer (A).
3. Using pipe sealant on the thread of the larger
end of tting, screw the propane/LP burner air
mixer (A) through hole and into burner manifold
as shown in Fig. 3. Tighten using a wrench.
Fig.3
A
The pilot is provided with a natural gas injector
installed. For Propane/LP gas you must remove
it and replace it with the Propane/LP injector (J)
(“LP” printed on the surface).
1. Gently loosen and remove the pilot gas pipe
from bracket. Replace the injector with the
Propane/LP pilot injector (J) with “LP” printed on
injector surface. Place and tighten the pilot gas
pipe to bracket as shown on Fig 1.
Changing Pilot Orice
J
Fig. 1
Follow steps 1 through 7 under Natural
Gas Installation, page 4.
Continue with step 3 under Natural Gas
Installation, page 4.