Figure 5 - Removing Front Panel
INSTALLATION
1. Carefully remove bulb clips with ther-
mostat sensing bulb from the shipping
position in the back panel.
2. Slide thermostat sensing bulb out of the
2 clips.
3. Carefully route thermostat sensing bulb
out of shipping position hole in the back
panel and into the relocation position hole.
If necessary, loosen wiretie securing capil-
lary. DO NOT kink capillary.
4. Insert bulb clips into 2 rectangular slots
parallel to the bottom of heater (relocation
position). Slide thermostat bulb through
clips. If clips are damaged use clips lo-
cated in the hardware package.
Screw
Front
Panel
REMOVING FRONT PANEL
1. Remove 4 screws securing front panel.
2. Carefully slide front panel forward.
INSTALLING THERMOSTAT SENSING BULB
For Heaters with Blower Installed Only
Figure 6 - Moving Thermostat Sensing
Bulb
Thermostat
Sensing
Bulb
Shipping
Location
Route
Thermostat
Sensing
Bulb into
Hole
Thermostat Sensing Bulb Relocation Position
Bulb Clip
Capillary
Thermostat Sensing Bulb