FIB100 BLOWER ACCESSORY INSTALLATION INSTRUCTIONS Spanish/Español Page 13 WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-866-573-0674, 7:30 am - 4:15 pm EST, Monday through Friday or email customerservice@usaprocom.
PACKAGE CONTENTS A B C D E Parts included with this kit Item A B C D E Part No. XB001-01 XB002-01F XB003-01 XB004-01F PF06-0400-A Description Qty Power Cord 1 Blower 1 Temperature Sensor 1 Connect Wire 1 Rocker Switch 1 Hardware Item AA BB CC Part No. GB/T 845-4.2*9.5F VL057-01 4*8 Description Qty M4.2x8 Screw 6 Cable Tie 6 M4.0x8 Screw 1 BB AA CC If any of these pieces are missing or damaged call ProCom Heating, Inc. at 1-866-573-0674 for referral information. 2 www.usaprocom.
SAFETY IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty. • Read all instructions before using this appliance. • If possible always unplug this appliance when not in use. • Do not operate any heater with a damaged cord or plug or after the appliance malfunctions, has been dropped or damaged in any manner.
PREPARATION Note: This blower contains assembly instructions for the following models and item numbers. For the CRHFD28TCM-6-AU, CRHFD32RT-M-MO, FBD28 and FBD32 series, PC32VFC and PC36VFC.
INSTALLING TEMPERATURE SENSOR WARNING: Before installing the blower, be certain to turn off the unit, and allow time for unit to cool down. 4. Insert wires into the space between wire protecting board and shell. Attach the wires to the top cover with wire routing clip. Wire Routing Clip 1. Remove upper firebox by unscrewing left and right screws on the firebox (see Figure 1). Protecting Board Figure 4 - Attaching Wiring Figure 1 - Remove Upper Firebox 2.
INSTALLING BLOWER ASSEMBLY CRHFD28TCM-6-AU, CRHFD32RT-M-MO, FBD28 and FBD32 Series Only 1. CRHFD32RT-M-MO and FBD32 Series 3. Set blower plane and attach to two brackOnly Remove 2 screws securing panel as ets of shell board. Make sure blower is shown in Figure 6. Remove panel to gain installed into the slots (see Figure 8). access to blower compartment. Screws Install Blower into Slots Figure 8 - Positioning Blower Assembly to Shell Board Blower Access Panel Figure 6 - Removing Blower Access Panel 4.
INSTALLING BLOWER ASSEMBLY PC32VFC and PC36VFC Series Only 1. Remove blower access panel (see Fig- 2. Mount blower onto blower access panel, ure 10). (see Figure 11). Figure 10 - Removing Blower Access Panel Figure 11 - Attaching Blower Assembly to Blower Access Panel 3. Carefully insert blower and wiring through access hole. Reinstall blower access panel with screws removed in step 1. CONNECTING POWER SUPPLY 1. Insert power cord wires through hole in side of firebox. 2.
CONNECTING POWER SUPPLY 4. Insert the male port from the blower assembly into the corresponding female port from the power cord, (see Figure 14). 7. Insert the female port, which is on the white power supply wire (marked with P1), into the corresponding male port. (marked with P1), (see Figure 18). P1 Female Port Male Port Blower Assembly Figure 14 - Attaching Blower to Power Cord Figure 17 - Connecting P1 Wires 5.
ELECTRICAL CONNECTION A 15 amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required. The fireplace should be on a dedicated circuit. Other appliances on the same circuit may cause the circuit breaker to trip, or the fuse to blow when the heater is in operation. Plan the installation to avoid the use of an extension cord. Extension cords are for temporary use only.
OPERATION Using rocker switch, turn blower on and check for operation. Turn on rocker switch to the desired position. In the MAN position the blower will remain constantly on. In the AUTO position the blower will be controlled by the temperature sensor. To stop the operation turn rocker switch to the O position. CARE AND MAINTENANCE Always disconnect the appliance from the main power supply and allow it to cool before any servicing operation.
ELECTRICAL WIRING DIAGRAM Any electrical re-wiring of this appliance must be done by a qualified electrician. This wiring must be done in accordance with local codes and/or in Canada with the current CSA C22.1 Canadian Electrical Code, and for US installations, the National Electrical Code ANSI/ NFPA NO 70. WARNING: If repairing or replacing any electrical component or wiring, the original wire routing, color coding and securing locations must be followed.
WARRANTY KEEP THIS WARRANTY Model ________________________________ Serial No. _____________________________ Date Purchased ________________________ Keep receipt for warranty verification. REGISTER YOUR PRODUCT AT WWW.USAPROCOM.COM IMPORTANT: We urge you to register your product within 10 days of date of installation, complete with entire serial number which can be found on the rating plate. Please fill out the warranty information above for your personal records. Retain this manual for future reference.
FIB100 ACCESORIO SOPLADOR INSTRUCCIONES DE INSTALACIÓN ADVERTENCIA: INSTRUCCIONES PARA LA CONEXIÓN ELÉCTRICA A TIERRA Este aparato está equipado con un enchufe de tres clavijas (con conexión a tierra) para protegerlo contra el riesgo de descargas eléctricas y debe ser enchufado directamente a un tomacorriente de tres patas con conexión a tierra receptáculo.
CONTENIDO DEL PAQUETE A B C D E Piezas incluidas con este equipo Art. A B C D E Pieza # XB001-01 XB002-01F XB003-01 XB004-01F PF06-0400-A Descripción Cant. Cable de alimentación 1 Soplador 1 Sensor de temperatura 1 Cables conectores 1 Interruptor oscilante 1 Art. AA BB CC Pieza # GB/T 845-4.2*9.5F VL057-01 4*8 Hardware Descripción M4.2x9.5 Tornillo Amarre de cable M4.2x9.5 Tornillo Cant. 6 6 1 AA BB CC Si alguna de estas piezas falta o está dañado llamada ProCom Calefacción, Inc.
SEGURIDAD IMPORTANTE: Lea con atención todas las instrucciones y advertencias antes de comenzar la instalación. Si no se siguen las instrucciones, se puede provocar una descarga eléctrica o riesgo de incendio, lo que anulará la garantía. • Lea todas las instrucciones antes de usar este electrodoméstico. • Si es posible, siempre desenchufe este electrodoméstico cuando no lo use.
PREPARACIÓN Nota: Este soplador contiene instrucciones de montaje de los siguientes modelos y números de artículos. Para el CRHFD28TCM-6-AU, CRHFD32RT-M-MO, FBD28 y FBD32 series, PC32VFC y PC36VFC.
INSTALACIÓN DEL SENSOR DE TEMPERATURA ADVERTENCIA: Antes de instalar el ventilador, asegúrese de apagar la unidad, y dar tiempo para que la unidad se enfríe. 4. Inserte los cables en el espacio entre el cable y el tablero de protección shell. Conecte los cables de la cubierta superior con el clip de enrutamiento de cables. Clip de enrutamiento de cables 1. Retire la cámara de combustión superior desatornillando los tornillos izquierdo y derecho en la cámara de combustión (consulte la figura 1).
INSTALACIÓN DEL CONJUNTO DEL VENTILADOR CRHFD28TCM-6-AU, CRHFD32RT-M-MO, FBD28 y FBD32 Series Sólo 1. CRHFD32RT-M-MO y FBD32 Series 3. Definir plano del ventilador y conectar a Sólo Retire 2 tornillos de fijación del panel dos soportes de placa shell. Asegúrese como se muestra en la Figura 6. Retire de ventilador se instala en las ranuras el panel de acceso al compartimento del (consulte la Figura 8). ventilador.
INSTALACIÓN DEL CONJUNTO DEL VENTILADOR PC32VFC and Only Series PC36VFC 1. Retire el panel de acceso del soplador 2. Montar ventilador en el panel de acceso (consulte la Figura 10). del soplador (consulte la Figura 11). Figura 10 - Extracción del panel de acceso del soplador Figura 11 - Colocación de ensamblaje del soplador de al panel de acceso del del soplador 3. Inserte cuidadosamente ventilador y el cableado a través del orificio de acceso.
CONEXIÓN DE LA FUENTE DE ALIMENTACIÓN 4. Introduzca el puerto macho del conjunto del ventilador en el puerto hembra correspondiente del cable de alimentación (consulte la Figura 14). 7. Insertar el puerto hembra, que está en el cable de suministro de energía blanco (marcado con P1), en el puerto macho correspondiente. (marcado con P1), (consulte la Figura 18). P1 Ensamblaje Puerto mujer Varón del puerto del soplador Figura 14 - Colocación del soplador al cable de alimentación 5.
CONEXIÓN ELÉCTRICA Se requiere un circuito de 15 amperios, 120 voltios y 60 Hz con un tomacorriente correctamente conectado a tierra. Preferentemente, la chimenea debe estar en un circuito dedicado, ya que la conexión de otros artefactos al mismo circuito puede provocar que el interruptor de circuito se desconecte o que el fusible se funda cuando el calentador está en funcionamiento. Planifique la instalación para evitar el uso de una extensión eléctrica.
FUNCIONAMIENTO Con el interruptor oscilante, encienda el soplador y compruebe el funcionamiento. Gire el interruptor oscilante hasta la posición deseada. En la posición MAN (MANUAL) permanecerá continuamente encendido. El sensor de temperatura controlará la posición AUTO (AUTOMÁTICO). Para detener el funcionamiento, gire el interruptor oscilante hasta la posición O.
DIAGRAMA DEL CABLEADO ELÉCTRICO Todo nuevo cableado eléctrico del electrodoméstico debe realizarlo un electricista calificado. Este cableado se debe realizar de acuerdo con códigos locales o, en Canadá, de acuerdo con el Código de Electricidad de Canadá CSA C22.1 actual, y para las instalaciones en EE.UU., de acuerdo con el código nacional de electricidad, ANSI/NFPA No. 70.
GARANTÍA GUARDE ESTA GARANTÍA Modelo___________________________________ Número de serie___________________________ Fecha de compra __________________________ Conserve su recibo para la verificación de la garantía. REGISTRE SU PRODUCTO EN WWW.USAPROCOM.COM IMPORTANTE: Le pedimos que registre su producto dentro de los 10 días de la fecha de instalación, lleve a cabo con el número de serie completa que se puede encontrar en la placa de características.