SPECIFICATIONS
Model FBNSD28T
Gas Type Natural Gas Propane Gas
Ignition Piezo Ignitor Piezo Ignitor
Maximum Input Rating
26,000 Btu/Hr 26,000 Btu/Hr
Minimum Input Rating
19,000 Btu/Hr 20,000 Btu/Hr
Pressure Regulator Setting 4" W.C. 9" W.C.
Inlet Gas Pressure* (inches of water)
(*for purposes of input adjustment)
Maximum 9.5" Maximum 14"
Minimum 5" Minimum 11"
Heater Dimensions (WxHxD) •
29.1" × 23.9" × 13.9"
Carton Dimensions (WxHxD) •
30.9" × 26.9" × 14.8"
Stove Weight • 47.6 lbs
Shipping Weight • 55.7 lbs
QUALIFIED INSTALLING AGENCY
Only a qualied agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser-
vicing. The term “qualied agency” means any
individual, rm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing,
or servicing equipment; that is experienced
in such work; that is familiar with all precau-
tions required; and that has complied with
all the requirement of the authority having
jurisdiction.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot shuts off the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic
piezo control system. This system requires
one AAA battery (provided).
THERMOSTATIC CONTROL
The control automatically cycles the burner
on and off to maintain a desired room
temperature.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
propane or natural gas. The heater is shipped
from the factory ready for connecting to pro-
pane. The heater can easily be changed to
natural gas by having your qualied installer
follow the instructions on page 10 and the