Problem Possible Cause Corrective Action
Log set produces a click-
ing/ticking noise just after
burner is lit or shut off.
1. Metal expanding while heat-
ing or contracting while cool-
ing.
1. This is common with most
log sets. If noise is exces-
sive, contact qualied ser-
vice person.
Log set produces un-
wanted odors.
1. Log Set burning vapors
from paint, hair spray, glues,
cleaners, chemicals, new
carpet, etc. (See IMPOR-
TANT statement page 16).
2. Gas leak. See Warning
statement page 16.
1. Open ue to maximum. Stop
using odor causing products
while log set is running.
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 9).
Gas odor even when
control knob is in OFF
position.
1. Gas leak. See Warning
statement page 16.
2. Control valve defective
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 9).
2. Replace control valve.
Gas odor during com-
bustion.
1. Gas leak. See Warning
statement at top of page 16.
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 9).
TROUBLESHOOTING