Full Product Manual

www.usaprocom.com
7160108-01C
ASSEMBLED IN THE USA BY:
ASSEMBLE AUX ETATS-UNIS PAR:
ENSAMBLADA EN LOS EE.UU.POR:
PROCOM HEATING, INC.
2800 GRIFFIN DRIVE
BOWLING GREEN, KY 42101
`
THERMOSTAT MODE
MODE/RESET
PUMP PRESSURE
STAND BY
ON/STOP
TEMPERATURE
MANUAL MODE
MODE MANUEL/MODO MANUAL
MODE/REINITIALISATION
`
MARCHE/ARRET
^
MODE THERMOSTAT
THERMOSTATO MODO
MODO/RESTABLECER
ENCENDER/APAGAR
TEMPERATURA
160167-02
PRESSION DE LA POMPE
PRESION DE BOMBA
`
ADJUST
AJUSTE
IMPORTANT: Review and under-
stand the warnings in the Safety
section, page 2. They are needed
to safely operate this heater.
Follow all local ordinances and
codes when using this heater.
TO START HEATER
1. Follow all ventilation and safety information.
2. Locate heater to provide maximum circu-
lation of the heated air. Follow all location
requirements noted in Safety, pages
2 and 3.
3. Fill fuel tank with fuel and attach fuel cap.
Use only kerosene, #1/#2 diesel/fuel oil,
JET A or JP-8 fuels to avoid risk of re or
explosion. Never use gasoline, oil drained
from crankcases, naphtha, paint thinners,
alcohol or other ammable fuels.
4. Plug heater’s power cord into approved,
grounded, three-wire extension cord.
Extension cord must be at least 6 feet
(1.8 m) long.
Extension Cord Size Requirement
6 to 10 feet (1.8 to 3 m) long, use 18
AWG (0.75 mm
2
) rated cord
• 11 to 100 feet (3.3 to 30.5 m) long, use
16 AWG (1.0 mm
2
) rated cord
• 101 to 200 feet (30.8 to 61 m) long, use
14 AWG (1.5 mm
2
) rated cord
5. Plug extension cord into standard 120
volt/60 hertz, 3-prong grounded outlet.
6. Push ON/STOP button to ON. An alarm will
sound and the display will start countdown
to ignition. The heater will start and pump
pressure will be displayed for 6 seconds.
7. Push MODE/RESET button to select
desired operating mode.
Note: When operating in Thermostat
Mode, press the MODE/RESET button
once to change to Manual Mode. When
operating in Manual Mode, Press the
MODE/RESET button twice within 5 sec-
onds to change to Thermostat Mode.
Manual Mode LED On: Adjust output to
desired setting. Press to raise the BTU
output. Press to lower the BTU output.
Note: After startup, heater BTU output can
be immediately adjusted, but adjustments
will not take effect for 2 minutes. This al-
lows the heater to stabilize.
Thermostat Mode LED On: Adjust ther-
mostat by pressing to change set point
higher. Press to change set point lower.
If thermostat set temperature is higher
than the surrounding air temperature by
F, the heater will ignite. If the thermostat
set temperature is lower than surrounding
air temperature, the heater will not ignite.
Heater output will adjust automatically to
maintain set temperature.
WARNING: This heater is
equipped with a thermostat.
Heater may start at any time.
TO STOP HEATER
1. Push ON/STOP button to stop heater.
2. Unplug heater when not in use.
TO RESET HEATER
1. Wait two minutes before restarting.
2. Push MODE/RESET button to restart
heater.
OPERATION
LED display will show surrounding temperature
unless up and down arrow keys are pressed.
After pressing these keys, display shows set
point temperature for ve seconds and then will
change back to display surrounding temperature.
Exposure to direct sunlight or extreme cold may
affect temperature reading and/or thermostat
operation.
This thermostat will store the last set point
even if power is removed. Unit will maintain
this set point until a new set point is entered.
Figure 5 - Controls Display
FAULT CODES
This heater will display fault codes whenever
there is a control shutdown. See Trouble-
shooting, pages 9 - 12, before attempting to
rectify any problems with your heater.