Instruction manual

INSTALLATION (Continued):
Plumbing:
The plumbing installation of this unit should only be performed by qualified technicians.
Verify that the water supply is shut off, and any
necessary lockout/tagout devices are properly
installed.
The customer supplied inlet and outlet plumbing must be rated for temperatures up to
275°F (135°C) at pressures up to 100 psi (6.9 Bar).
On all TYTAN units, the lower plumbing connection will always be the inlet, and the
upper plumbing connections will always by the outlet. The inlet plumbing to the unit
must include the means to drain the unit, which may be necessary in the case of
replacing the heating column or other parts.
Do not reverse the plumbing connections of
this unit. Failure to observe the correct
plumbing orientation will result in high-
temperature conditions and heater failure.
M-45-02 TYTAN Manual
Revision - Date: 01 – 11/16/07
18