Instruction manual

Model Number Explanation (continued):
TY-072-480-3-SC-RI
c d e f g
e Heater Voltage. The first character following the heater Wattage will describe
the rated Voltage of the heater.
f Heater Phase. This character will specify if this unit is designed for single
phase (-1) or three phase (-3) power.
g Options. The remaining characters will specify any options included in this
system. Many of these options can be combined on a single Tytan water heater.
Only a few options are mutually exclusive.
Model Number Option
-CB
Include circuit breaker with disconnect switch.
-SC Built to SEMI S3 standards, CE compliant version
(Includes –CB option)
-PLC PLC temperature controller, in place of the standard PID
controller
-RI Remote interface. This will allow the user to start, stop,
reset the unit and monitor the safety circuit remotely.
-RC1 RS485 communications interface with the Omron PID
temperature controller (requires optional E5CK
controller)
-RC2 RS232 communications interface with the Omron PID
temperature controller (requires optional E5CK
controller)
-RC3 4-20mA process output (requires optional E5CK
controller)
-S
Wetted surfaces to be passivated 316 stainless steel.
-X
Special option, consult factory
-##
Special construction design, consult factory for details
Table 5: TYTAN Options
M-45-02 TYTAN Manual
Revision - Date: 01 – 11/16/07