Installation manual
CM-02-001
TYTANu DI Water Heater
O.I. 6/27/03 Installation, Operation and Maintenance Manual
ECO page 4
Section 1: Introduction
The Process Technology TYTANu DI Water Heater is designed to accommodate normal fluctuations in flow and process
temperatures while providing a safe, energy efficient heater. The heating elements have a durable low watt density design which
gives the element a long service life while maintaining a high flow capacity. The heating elements and wetted surfaces of the DI
Water Heater are manufactured from either Titanium or Stainless Steel as ordered by the customer. The standard Process
Technology TYTANu DI Water Heater, consisting of the heating column(s) and the complete control system, is enclosed in an
wall-mounted or freestanding painted steel enclosure.
The standard TYTANuu DI Water Heater control system consists of the following:
PID based temperature controller with high-temperature alarm relays
Solid state control relays
Bi-metallic over- temperature Sensors
Over-temperature controller
GFP
Optional Equipment may include the following:
PLC controller
Circuit breaker and electrical disconnect
Built to SEMI and CE standards
Remote control electrical interface
RS-232, RS485 serial communication interface
Special inlet/outlet plumbing connections
Stainless steel heating column construction