Specifications

14
If the keypad has been mounted, press 2 any keys at the same time and press button A on the remote control to transmit a
signal: the keypad will produce 4 BEEPs to confirm reception. Release the 2 buttons and key in the override code within 10 sec:
the direction indicators flash 2 times and the siren produces 2 BEEPs to confirm the function has been activated.
It is possible to turn the ignition on 15 times when the garage function is operational and will remain memorised, even if the
alarm control units power supply is disconnected. To exit the garage function, arm the alarm system with the remote control.
THE CONTROL UNITS POWER SUPPLY
If the control units power supply is disconnected, its memory will store its previous status. When its power supply is restored,
the status of the control unit will be the same as just before the power supply was disconnected.
MEMORY OF TRIGGERED ALARMS
If various alarms have been triggered, the memory will signal them in sequence with 3 second pauses, and repeat the sequences
every 6 seconds. The memory is reset when the vehicles ignition is turned on or when the control unit is armed again by remote
control.
TYPE OF ALARM TRIGGERED
ULTRASONIC
DOORS
BONNET
BOOT
AUXILIARY MODULES (POSITIVE ALARM)
DASHBOARD (+15)
CURRENT DROP SENSOR
LED SIGNAL
1 FLASH
2 FLASHES
3 FLASHES
4 FLASHES
5 FLASHES
6 FLASHES
7 FLASHES
FINAL CHECK
After the alarm system has been installed and customised, it is important to check that it operates correctly by means of the
following procedure:
- connect the cables connector to the HPA control unit
- close the boot, sun-roof, all windows and doors
- make sure that you have not left the car keys or the remote controls inside the vehicle
- restore the connection of the car battery, then close the bonnet
- the first time it is switched on, the control unit will be disarmed
- start up the engine to check that all connections have been carried out correctly
The checks described below refer to a control unit with standard factory settings: the results of the various steps may vary
according to any customisation of the operating functions.
- arm the control unit by pressing button A on the remote control: the doors are locked by the central door locking system, the
alarm protection is operational, the direction indicators flash 2 times and the LED flashes
- during the initial 25 seconds of immunity time, complete the following tests, each of which should cause the indicators to flash
once, signalling the positive outcome of the test:
- open a door, the bonnet and the boot
- turn the ignition key ON
- insert your hand through an open window and move it backwards and forwards compared to the installed ultrasonic
capsules; the initial immunity time starts again from zero every time the indicators flash
- after the initial immunity time is over, the LED will flash more slowly and there will be a 25 second alarm cycle if you trigger
any of the alarms protection features: the siren produces its distinctive modulated sound, the direction indicators flash and
the horn ,if connected, sounds intermittently. Check that the immobiliser is working properly during an alarm cycle.
- disarm the alarm control unit by pressing button A on the remote control: the doors are unlocked via the central door locking
system, the direction indicators flash once, the M02 siren produces 1 BOOP sound, whilst the SC1 siren produces 2 BIPS, and
the LED flashes to indicate the memorised alarms which took place during the final check. Refer to the relative section for more
information on what these flashes stand for.
Please refer to the instructions of the individual auxiliary modules for more information on their operation, if any are installed.