User guide
821116: AMP2-16V Series User Guide
© 2011 Wohler Technologies, Inc. All rights reserved.
85
Chapter 5 Menu List
Arbitrary Phase Measurement Menu
Figure 5–7 Arbitrary Phase Measurement Menu
• Phase Compare A: Rotating this knob steps through the channels
(and also displays their functions as assigned on the Monitor
Mixer Configuration Menu
.) The channel(s) selected by Phase
Compare A
are the Reference Channels in each phase
comparison. Use this control in conjunction with Phase
Compare B
to set up each phase measurement relationship.
• Select Phase Pair: Rotating this knob moves the highlight from
channel pair to channel pair;. Pressing this control to light the
indicator enables a phase comparison between the two channels on
this line.
• Phase Compare B: Rotating this knob steps through the audible
channels (except for the one you have already selected in Phase
Compare A
). The channel(s) selected by Phase Compare B are
the Test Channels to be compared to the Reference Channels.
Use this control in conjunction with
Phase Compare A to set up
each phase measurement relationship.
The triangular arbitrary phase indications on the
Main Screen
function as follows:
Arbitrary Phase Measurement Menu
Save / ExitHelp Cancel
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Select
Phase Pair
Phase
Reference
Channel
Phase Test
Channel
Reference
Channel
Test
Channel
Indication
Color
Note:
The colors for each arbitrary phase indication are
automatically and sequentially selected.
Note:
The same channel may not be both a Reference Channel
and a
Test Channel.
Note:
Any given Reference Channel may be used in more than
one comparison.