User guide
821116: AMP2-16V Series User Guide
© 2011 Wohler Technologies, Inc. All rights reserved.
19
Chapter 2 Installation
Installation Recommendations
Safety Symbols
Installation Recommendations
Mounting
The unit is designed to install into a standard 19" rack mounted at ear
level for best high frequency response and visual observation of the
monitor screen. Please adhere to the following clearances:
Heat Dissipation
The ambient temperature inside the mounting enclosure should not
exceed 40° Celsius (104° Fahrenheit). Adjacent devices can be rack
mounted (or stacked) in proximity to the unit if this temperature is not
exceeded. Otherwise, allow a 1RU (1.75”/44.45mm) space above and
below the unit for air circulation.
WARNING:
The symbol to the left warns of electric shock hazard inside the unit.
Disconnect the power cord before removing access panels when
installing upgrades. Only qualified service personnel are to operate the
equipment with covers removed, and are to exercise caution to avoid
personal injury.
Clearance Surface
24” Front
3” Rear
2” Sides
1.75” Top and Bottom (if either radiates heat)
0” Top and Bottom (if no heat)
Important:
To reduce noise, the monitor does not have any fans. As a result, the
heat generated by the class D power amplifiers, power supplies, and
other components is vented by slots in the side of the unit. Therefore,
as a safety precaution, you must allow proper ventilation on both sides
of the unit.