User guide

821116: AMP2-16V Series User Guide
© 2011 Wohler Technologies, Inc. All rights reserved.
115
Chapter 5 Menu List
Meter Configuration Menu
Ballistics: Rotating this knob adjusts the float. Pressing and then
rotating adjusts the bar. Ballistic timings are valid only at 48 kHz.
Limits: Rotating this knob sets the upper limit of the display.
Pressing and then rotating sets the lower limit. Top and bottom
limits are adjustable in 1 dB increments. This function is available
on the custom meter scale only.
Lower Scale: (This function is available on the custom meter scale
only.) This knob controls the size of the lower part of the scale in
relation to the overall scale. You can reduce the size of the lower
part of the scale to allow more accuracy in viewing the upper part.
Rotating this button sets the division point between the upper and
lower parts of the scale in 1 dBr increments and it moves the arrow
in the meter display up or down. As you adjust the division, the
percent of full scale (%FS) in the
Size section of this function, is
continuously recalculated. Likewise, if the Limits control is
adjusted, the %FS is also recalculated.
Pressing the knob and then rotating it adjusts the %FS. This value
cannot be adjusted to a number in excess of the calculated %FS.
Rotating the knob counter-clockwise reduces the %FS in 1%
increments. It may not be adjusted to less than 5%.
BBC
(EBU)
-13.25 dBr +13.0 dBr -18 dBFS = 0 dBr 0 dBr 8 dBr IEC Type II
Nordic -44 dBr +12.5 dBr -18 dBFS = 0 dBr -10 dBr 0 dBr IEC Type I
DIN -53 dBr +5.5 dBr -15 dBFS = 0 dBr -5 dBr 0 dBr IEC Type I
Custom
-72 dBr
(min) (2)
+20.0 dBr
(max) (2)
0 dBFS = 0 dBr -30 dBr -20 dBr
IEC
Type I
VU
Table 5–1 Meter Limits and References (Continued)
Scale
Bottom
Limit
Top Limit
Default
Reference
Default Color
Bounds
Default Ballistics
Lower Upper Float Bar
Table 5–2 Meter Timings
Ballistics Rise
Fall
Level
Change
Time
VU Not Specified
IEC Type I
5 ms to reach -2 dB of
settled reading
-20 dB 1.7 sec.
IEC Type II
10 ms to reach -2 dB of
settled reading
-24 dB 2.8 sec.
None Bar or Floating Segment Not Displayed