User Manual

InstructionsforFixtureMountingandCordConnection:
1.Thelightfixturewithcordisprewiredatthefactoryfor120voltoperation.
2.Securefixtureindesiredlocationbyplacingselflockinghookaroundeyebolt,chain,cableor
othersuitablemount.OVERHEADHAZARD‐
MAKESUREFIXTUREISSECURE.
3.Withlamp,safetycageandbottomguardinplace,connectfixtureto120V electricalserviceusingthe
powercordsupplied.DONOTCONNECTfixturetopowersourcewithsafetycage,lamporbottom
guardmissing.
4.Useonly3wireextensioncordsoftheappropriatetype,lengthandgaugeforthespecific
circumstancesandmakesureallcordsandplugsareingoodcondition.
5.Makesureallelectricalconnectionsaresecure.Keepcords
securewithcabletiesorotherappropriate
means.
InstructionsforRewiringtheFixturetoaPowerSupplyOtherthan120Volts:
1.Thelightfixturewithcordisprewiredatthefactoryfor120voltoperation.
2.DISCONNECTFIXTUREFROMPOWERSOURCE.Removethesafetycage,lampandbottomguard.
3.Locatetheaccessplatewithtwo(2)knockoutsononesideofthefixturehousing.Removethetwo(2)
screwsthatholdtheaccessplatetothehousing.
4.Disconnectandremovethefactorysuppliedpowercord.DONOTUSEthepowercordatanyvoltages
otherthan120voltsAC.
5.Removeoneofthe3/4”
knockoutsintheaccessplateandroutethenewincomingpowercord(usersupplied)
throughtheknockouthole.
6.Useastrainreliefbushingorconduitfitting(usersupplied)tosecureandprotectthenewpowercord.
7.Identifytheappropriateleadforthedesiredelectricalservice(208V,240Vor277V)andremovecapfrom
thislead.Makeallnecessaryconnectionsandcapoffanyunusedleads.
8.Reattachtheaccessplatetothehousing.
9.Installthesafetycage,lampandbottomguardaccordingtoinstructions.
10.Mountfixtureandconnecttoappropriateelectricalsource.
WARNING
!
Verifyallwiringconnections.
Insurethatthepropervoltageleadsonthelightfixturehavebeenselectedtomatchthesupplyvoltage.
Improperwiringmaydamagethetransformerandresultinfire,personalinjuryorpropertydamage.
ManufacturedbyProBuilt
ProfessionalLighting,LLC‐
1170AllansonRoad,Mundelein,IL60060
TollFree:8777070800www.wobblelight.com
E
EISA
Compliant
CAUTION
!
MetalHalidelampsemitultraviolet(UV)radiation
Donotstareatexposedlampwhileoperating
Possibleskinoreyeirritationcanoccurfromexposure>15minutes
HOTSURFACES–Donotrelamp,moveorservicefixtureuntilithascooled.
ProductRegistration:Toreceiveimportantproductinformationandupdatespleasefollowthesesteps.
1.Sendanemailtocustomerservice@wobblelight.com.
2.Posttheword“registration”
inthesubjectfield.
3.Includeyourname,company,address,phonenumberandtypeofmodelpurchased.
4.Ifyouprefertoregisterbyphone,pleasecallWobblelight®
CustomerCareat8777070800between
thehoursof8:30a.m.and5:00p.m.(U.S.CentralTime).
090929Rev.A