Installation Guide
MOUNTING INSTRUCTIONS:
JUNCTION BOX MOUNTING:
1. Unscrew 4 screws to open back box (Fig. 1)
2. Knock-out desired J-box mounting hole locations
3. Thread wire through hole in back housing and make wire
connections in j-box
4. Place gasket between back housing and J-box then fasten
securely to J-box
5. Re-attach xture to back housing
SURFACE MOUNTING:
1. Unscrew 4 screws to open back box (Fig. 1)
2. Knock-out desired mounting hole locations
3. Place gasket between wall and back housing and then secure
housing to wall
4. Remove plug from desired conduit entry location and attach
conduit, then make wiring connections
5. Re-attach xture to housing
AIMING:
Loosen hex bolt to aim head to desired location, then fasten
bolt securely.
WALL PACK LIGHT
26W
15.00’’ x 8.45’’ x 11.65’’
FIGURE 1
FIGURE 2
SUITABLE FOR WATTAGES:
MOUNTING INSTRUCTIONS
CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened rmly. Apply
weatherproof silicone sealant (NOT included) around the edge of the Wall Box and/or Junction Box. This is especially important with an
uneven wall surface. Silicone all plugs and unused conduit entries.
IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE.
This xture must be wired and installed in accordance with the NATIONAL ELECTRICAL CODE and all state and applicable local codes
and ordinances. These codes and ordinances supersede any and all instruction contained herein. Installation should be performed only by
a licensed and bonded electrician and a person familiar with the construction and operation of the product and the hazards involved in the
installation and operation of this product. Proper grounding is required for safety. Make certain power is OFF before installing or maintaining
xture. Failure to do so may increase the RISK OF PERSONAL INJURY, PROPERTY DAMAGE, FIRE, AND DEATH. The manufacturer takes
no responsibility for the product not installed under those guidelines and those contained in this document. See wiring diagram on back.
8.45 in
215 mm
11.65 in
296 mm
2.85 in
72 mm
8.45 in
215 mm
15.00 in
380 mm
4.25 in
108 mm
VER08.16
FIXTURE IS SUITABLE FOR WET LOCATION