Specifications
PRO WELD
CD-212 GAP
Adjustment of stud welding gun
Adjustment of stud collet
For different stud diameters, different collets are required.
Adjust collet as follows:
* Loosen counternut (3)
*
Insert stud (1) into collet.
The top edge of the stud flange must project for about .06 (1.5 mm) from the
front edge of the co
llet.
* Adjust stop screw (4) in the collet by turning it until the distance from
the top edge of the stud flange to th
e front edge of the collet equals
.06 inches (1.5 mm).
* Lock stop screw (4) by means of counternut (3).
* The following ta
ble indicates which tripod leg length is required.
Stud Length
Leg Length
Part #
0
–
1 3/8
2”(standard)
F01358
1/2
–
1 7
/8
2 1/2”
F01359
1
–
2 3/8
3”
F01360
2
–
3 3/8
4”
F01361
1. Stud
3. Counternut
2. Collet
4. Stop Screw
NOTE:
The stud must make contact with the stop screw(4).
Page