User Manual
NEVER LEAVE HEATER UNATTENDED 
WHILE BURNING OR WHILE CONNECTED 
TO A FUEL SOURCE
© 2017, Pinnacle Climate Technologies, Inc.  Propane Tank Top Heater User’s Manual 
®
Assembly
PT-47-TTC (Continued):
 – To have all 3 burners face front, the plane 
washer should be to the right side of tank collar 
bracket. (See Figure 6)
 – To have far left burner face back, the plane 
washer should be to the left side of tank collar 
bracket. (See Figure 6)
 Figure 6
Connecting Heater to LP Cylinder:
Be sure to read and understand all of the Safety 
Information in this manual before connecting 
the heater to the LP cylinder. Installation must 
conform to local codes and with the Standard 
for the Storage and Handling of Liquefied 
Petroleum Gasses and ANSI/NFPA 58.
Inspect the hose and regulator prior to each use 
of the heater. If there is excessive abrasion or 
wear, or if the hose is cut, replace it with the 
proper assembly shown in the parts list prior to 
using the heater.
Model PT-16-TTC:
1.  Be sure that the control knob on the regulator 
is in the “OFF” position.
2.  Line up the threads on the fuel connector nut 
with the threads on the LP cylinder valve. Turn 
fuel connector nut COUNTERCLOCKWISE to 
tighten. Fully tighten the nut, being careful not 
to over tighten. 
3.  Slowly open the LP cylinder valve.
Models PT-32-TTC / PT-47-TTC:
1.  Be sure that the control knob on the regulator 
is in the “OFF” position.
2.  Line up the slots in the tank collar bracket 
with the tank collar ring and slide into place. 
Be sure the mounting knob is to the outside, 
and tighten.
3.  Line up the threads on the fuel connector nut 
with the threads on the LP cylinder valve. Turn 
fuel connector nut COUNTERCLOCKWISE to 
tighten. Fully tighten the nut, being careful not 
to over tighten. 
4.  Slowly open the LP cylinder valve.
Check all connections for leaks using a 50/50 
mixture of dish-soap and water. Any bubbles 
that appear show a leak. Remove and 
reconnect the Connector Nut to the valve.
DO NOT direct the heater 
discharge towards any 
propane cylinder located within 20 feet of 
the heater.
WARNING
7