3 Controls & Displays
Laser Controls
Power Switch turns the laser on and off.
Cone Scale set conical reference ±4%
X axis Leveling LEDs: green LED lights when unit is leveling, both red
LEDs (X & Y axis) flash if a leveling limit is reached.
Y axis Leveling LEDs: green LED lights when unit is leveling, both red
LEDs (Y & X axis) flash if a leveling limit is reached.
Y Axis Manual LEDs: amber LED lights when in Slope Matching mode,
red LED flashes (with X red LED) if leveling limit is reached.
Power LED is lit green when unit is on. When the laser finishes leveling,
the LED will flash 5 times, indicating that the Height Alert
is active.
Battery Life Indicator flashes amber when battery power is low.
Manual Slope Switch, a deliberate (1/2 second) press and release will set
the laser into manual grade matching mode. Laser continues to self level in
the cross axis, but is not self leveled in the slope axis.
Manual Slope Control Switches are used to tilt the laser plane to the de-
sired slope.
Receiver Controls & Display
Power Switch turns receiver on & off
Volume Switch toggles sound from high to low to off.
On Grade Accuracy Switch toggles from standard to fine to coarse.
Low Battery Volume
High coarse (both
segments)
High fine
Low coarse (both
segments)
Low fine
On Grade
Accuracy, (left to right),