Product Manual

Sump Pump Switch
Electronic Sump Pump Switch
®
®
®
®
®
Fluid Control Products
www.LevelGuardProducts.com | 11
Trouble-Shooting for LevelGuard® Sump Pump Switch
1. Sump Pump Control cord improperly
plugged into receptacle.
2. Pump cord improperly plugged
into Sump Pump Control plug.
3. Blown panel fuse or breaker.
4. GFCI receptacle tripped.
5. Low Voltage.
6. Main Power Outage.
7. Defective Pump.
8. Contamination build-up on
Sump Pump Control exterior.
9. Improper Mounting / Loose.
10. Damaged or defective Sump
Pump Switch.
1. Signicant in-ow of water.
2. Sump Pump Switch mounted
facing inlet pipe.
3. Defective check-valve.
4. Defective Pump.
5. Excessive Temperature.
6. Improper Mounting / Loose.
7. Damaged or defective Sump
Pump Switch.
1. Contamination build-up on Sump
Pump Control exterior.
2. Improper Mounting / Loose.
3. Foreign conductive object near
sensor pad.
4. Damaged or defective Sump
Pump Switch.
1. Properly insert plug into receptacle.
2. Properly insert pump cord into Sump
Pump Switch piggyback plug.
3. Replace with proper sized fuse
or reset breaker.
4. Reset GFCI receptacle.
5. If voltage under 108 volts, contact
qualied electrician.
6. System will not work without power.
7. See Pump Manufacturer’s Operators
Manual.
8. See Maintenance Guide for proper
cleaning instructions.
9. See Sump Pump Control Installation
Instructions.
10. Contact LevelGuard Customer Service.
1. Normal. Check Pump Specication to
conrm adequate pumping capacity.
2. Move Sump Switch Control away from
inlet pipe.
3. Replace check-valve.
4. See Pump Manufacturer’s Operator
Manual.
5. Let system cool down for 5 minutes.
6. See Sump Pump Switch Installation
Instructions.
7. Contact LevelGuard Customer Service.
1. See “Maintenance Guide for proper
cleaning instructions.
2. See Sump Pump Switch Installation
Instructions.
3. Remove foreign object.
4. Contact LevelGuard Customer Service.
Pump will
not start or
run
Pump
starts
and stops
too often
Pump will
not shut
o when
water is not
present at
the lower
limit
Symptom Possible Root Cause(s) Potential Corrective Action